84090477 Product Catalogue hg bath and kitchen 2023 en_EX w…

hansgrohe Planning & installation

Technical details, assembly tips and installation information

iBox universal, front and side views

# 01800180 Operating pressure:

The base set can be fitted to suit the structural conditions. The iBox universal is suitable for both bath tub and shower installation. With single lever bath mixers, the lower outlet (outlet 1) has priority. With shower installations, the outlet that is not required needs to be stopped with a plug.

Tips for raw installation Fit the base set with the hot water connection on the left and the cold water connection on the right.

max. 1 MPa 0.1–0.5 MPa

Recommended operating pressure:

1.6 MPa (1 MPa = 10 bar = 147 psi)

Test pressure:

Installation depth: 80 mm to 108 mm.

Hot water temperature:

max. 80 °C

The rotation-symmetrical base set of the iBox universal can be used horizontally or vertically.

Recommended hot water temperature: 65 °C

Extension set 25 mm for too deep installation: # 13595000 Extension set 22 mm

Connection dimensions:

Exception: installation of bath mixers with safety combinations; only vertical installation is possible here.

Connections:

cold right, warm left 0.3 MPa 31 l/min 24 l/min 32 l/min

Free flow at:

for too shallow installation depths: # 13596000 for wall flanges 170 mm diameter # 13593000 for ShowerSelect # 13601000 for ShowerSelect including FixFit and porter # 13604000 for ShowerSelect glass

Bath mixer outlet bath tub: Bath mixer outlet shower:

Shower tap:

Thermostatic mixer: 43 l/min Thermostatic mixer with shut-off valve: 26 l/min Thermostatic mixer with shut-off and diverter valve: 26 l/min Thermostatic mixer Highflow: 48 l/min Test mark:

DVGW, SVGW

Flushing Complete installation as per DIN 1988/EN 1717, part 2, Flushing. The arrows on the flushing block indicate which inlet is connected to which outlet pipe, for instance cold water to outlet 1 and hot water to outlet 2. If only outlet 1 is required, then the flushing block needs to be rotated by 90° after the first flush.

Tips for the bath tub

Outlet 2

(A)

Place bath tub: 1. Switch off water

iBox universal in combination with Exafill bath filler with waste and overflow set:

Hot

Cold

2. Install bath tub with Exafill and connect to mains water 3. Flush pipe to Exafill with sample filler necks and check for leaks 4. Switch off water at floor level 5. Remove flushing block 6. Insert plug (A) in outlet for Exafill

switch off water to the Exafill during the construction stage!

Raw installation: 1. Install iBox universal 2. Lay pipelines to Exafill and block (metal plug) 3. Flush and press pipe system

7. Fit flushing block 8. Switch on water

Outlet 1

You can find videos and tips on installation at youtube.com/hansgrohe

395