Mold Components

INTERNAL LATCH LOCK Set-Up Dimensional Information

DME AX-Series stripper plate mold base is

DME AX-Series stripper plate mold base is shown

BCP

C

B Plate

X-1 Stripper Plate

A Plate

TCP

Support Plate

4 mm (.157") Minimum

Positive Stop

T rTavel for Latch Body

Z

L8

2nd parting line opening occurs when latch releases Top end ofcenterpulerpin

W

Y

1st parting l opening for built-in trav

T rTavel for X-1 Stripper Plate

IMPORTANT SET-UP DIMENSIONS (Refer to Drawing Above)

L8 BODY FOR CAM FINGERS LENGTH DIMENSION

W (2) CENTER PULLER PIN SET-UP DIMENSIONS

Y (3) MOUNTING PLATE THICKNESS RANGE

Z (4) C’BORE DEPTH IN MOUNTING PLATE

“T” (1) TRAVEL RANGE

BASIC LATCH SIZE

INTERNAL LATCH LOCK ASSEMBLY ITEM NUMBER

MINIMUM MAXIMUM mm in mm in

mm

in

mm

in

mm

in

mm

in

DKL2811

5

.197 30 1.181

22 to 35

.866 to 1.378

28mm DIA (Small)

+.0016 -.0000 .3937

+0.04 -0 10

DKL2812 DKL2821

23 ±0.1

40

1.575

.906 ±.004

30 1.181 55 2.165

DKL2822

DKL3411

6

.236 41 1.614

27 to 47.6

1.063 to 1.875

34mm DIA (Medium)

+.0016 -.0000 .4724

+0.04 -0 12

DKL3412 DKL3421

32 ±0.1

51

2.008

1.260 ±.004

41 1.614 76 2.992

DKL3422

DKL4511

12

.472 58 2.283

35 to 60

1.375 to 2.375

45mm DIA (Large)

+.0016 -.0000 .6299

+0.04 -0 16

DKL4512 DKL4521

43 ±0.1

68

2.677

1.693 ±.004

58 2.283 104 4.094

DKL4522

DKL6011

15

.590 80 3.149

46 to 86

1.811 to 3.385

60mm DIA (Extra)

+.0016 -.0000 .7874

+0.04 -0 20

DKL6012 DKL6021

58 ±0.1

92

3.622

2.283 ±.004

80 3.149 130 5.118

DKL6022

(1) Supplied to provide maximum travel with no cut off. To reduce travel between maximum and minimum, cut off slotted travel limiting sleeve on threaded end only per installation data. Cut off to no less than minimum travel; maintain close tolerances per installation data. (2) This set-up dimension is critical and must be maintained as specified to properly locate pin and cam body to latch. Dimension W is from top of X-1 stripper plate to top end of center puller pin. See installation data for additional information. (3) “Y” mounting plate dimension will be the “A” plate for AX-Series stripper plate mold bases. (4) This counterbore depth is critical and must be maintained as specied to locate split sleeve, cam body, and pin to latch.