CAVITY AND CORE COMPONENTS Mold Dating Inserts Hi-Temperature/Blind Hole Features of Hi-Temperature Mold Date Inserts • Withstands temperatures up to 644oF (340oC) • Designed to be easily removed from cavity plate with a metric screw, no need for a thru-hole • Newly engineered inner insert is removed with less rotations due to shorter threads • Inner inserts use ball detents to click into position
Dimensions and Tolerances of High-Temperature Inserts
OUTER INSERT
INNER INSERT
Material: Stainless Steel Hardness: 50-55 HRC Max. Temp: 340°C (644°F) Dimensions: All dimensions are in mm, except as noted
D(m6)
F(h7)
F(h7)
K
L +/-.02
M
D(h7)
Hi-Temp Blind Hole Inserts
D
OUTER INSERT
INNER INSERT
TOLERANCES
Ø D (m6)
Ø F (h7)
L
M Ø F (h7)
K
m6
h7
4 6 8
2.6
8 M1.8 8 M2.5
2.6
5.5 5.5 7.1 8.8 9.8 9.8
+0.012 TO +0.004 +0.012 TO +0.004 +0.015 TO +0.006 +0.015 TO +0.006 +0.018 TO +0.007 +0.018 TO +0.007 +0.021 TO +0.008
0 TO -0.012 0 TO -0.012 0 TO -0.015 0 TO -0.015 0 TO -0.018 0 TO -0.018 0 TO -0.021
4
4
5.0 6.3 7.5
10 12 14 14 16
M3 M3 M4 M5 M5
5.0 6.3 7.5
10 12 16 20
11.0 13.2
11.0 13.2
11.8
Removing Hi-Temperature Inserts
Cap Bolt
Inner Insert
Plate
Outer Insert
Continue turning the cap bolt clockwise raising the outer insert up from the plate.
Remove the inside insert. Insert cap bolt into outer insert hole.
Turn the cap bolt clockwise into the outer inserts under threads.
Remove the outer insert from the plate when it has cleared the hole.
2 08