CAVITY AND CORE COMPONENTS Tunnel Gate Inserts INSTALLATION DIMENSIONS GTR/GTE, GTM, GMK

Recommended distances (L) from the injection point to the sprue ejector are given in the table below for various material groups. The distance (AT) describes the correlated ejector depth.

PLASTIC GROUP

GTR/GTE GTM GTK GXK GMK

HD-PE, LD-PE, PET, PP, PA, PC, PVC. (L)

>20

>15

>25

>35

>30

RUNNER DESIGN

ROUND

EJECTOR DEPTH (AT)

>16

>11

>20

>35

>30

ABS, M ABS, ASA, PS, PC/ABS, POM, PBT. (L)

>25

>20

>30

>40

>35

RUNNER DESIGN

ROUND

EJECTOR DEPTH (AT)

>20

>14

>24

>40

>35

ELASTOMER TPE, TPU, TPP, TPA. (L)

>15

>15

>20

>30

>25

RUNNER DESIGN

ARBITRARY

EJECTOR DEPTH (AT)

>11

>11

>16

>30

>16

BRITTLE PLASTICS (L)

>30

>25

>40

UPON REQUEST

RUNNER DESIGN

HALF-ROUND

EJECTOR DEPTH (AT)

>24

>18

>32

UPON REQUEST