MOLD ASSEMBLY Permanent Magnetic Lifters
Bunting® MagLift Permanent Magnetic Lifters are powered by blocks of high-energy neodymium magnetic material. Switching is achieved by making one of these blocks reversible. In the “on” position, the reversible block is in parallel with the static blocks so that a concentrated magnetic field is produced at the pole feet for lifting. In the “off” position, the reversible block is rotated through 180° to provide a total magnetic short circuit within the lifter body.
Force/Air Gap Curve – Hand Controlled
Standard Magnetic Lifter
Dimensions
Flat Section
Round Section
Safe Work Load (lbs)
Min. Thick- ness (in)
Safe Work Load (lbs)
Max Dia- meter (in)
Lifter Weight (lbs)
Max Length (inches)
Max Length (in)
A (in)
B (in)
C (in)
D (in)
E (in)
F (in)
Model
MAGLIFT275 MAGLIFT550 MAGLIFT1100 MAGLIFT2200 MAGLIFT4400
9.9 4.3 5.9 3.0 2.4 2.1 5.9 275 18.7 6.5 8.3 3.5 2.8 3.0 7.9 550 38.5 8.9 11.1 4.2 3.5 4.1 9.6 1100 80.3 12.8 15.4 5.4 4.1 4.4 14.4 2200 173.8 15.7 19.0 7.3 5.2 6.7 20.7 4400
0.6 0.8 1.0 1.4 2.8
60 60 80
110 10 220 12 440 16 880 18 1760 24
60 60 80
120 120
120 120
The maximum stated length is not the maximum diameter. (Always work within the stated Safe Work Load) Above values are based on cold-rolled mild steel.
389
U.S. 800-626-6653 ■ Canada 800-387-6600 ■ Mexico 52-442-713-5666 ■ dme.net ■ store.dme.net
Made with FlippingBook - professional solution for displaying marketing and sales documents online