Mold Components

MOLD ASSEMBLY Permanent Magnetic Lifters

Bunting® MagLift Permanent Magnetic Lifters are powered by blocks of high-energy neodymium magnetic material. Switching is achieved by making one of these blocks reversible. In the “on” position, the reversible block is in parallel with the static blocks so that a concentrated magnetic field is produced at the pole feet for lifting. In the “off” position, the reversible block is rotated through 180° to provide a total magnetic short circuit within the lifter body.

Force/Air Gap Curve – Hand Controlled

Standard Magnetic Lifter

Dimensions

Flat Section

Round Section

Safe Work Load (lbs)

Min. Thick- ness (in)

Safe Work Load (lbs)

Max Dia- meter (in)

Lifter Weight (lbs)

Max Length (inches)

Max Length (in)

A (in)

B (in)

C (in)

D (in)

E (in)

F (in)

Model

MAGLIFT275 MAGLIFT550 MAGLIFT1100 MAGLIFT2200 MAGLIFT4400

9.9 4.3 5.9 3.0 2.4 2.1 5.9 275 18.7 6.5 8.3 3.5 2.8 3.0 7.9 550 38.5 8.9 11.1 4.2 3.5 4.1 9.6 1100 80.3 12.8 15.4 5.4 4.1 4.4 14.4 2200 173.8 15.7 19.0 7.3 5.2 6.7 20.7 4400

0.6 0.8 1.0 1.4 2.8

60 60 80

110 10 220 12 440 16 880 18 1760 24

60 60 80

120 120

120 120

The maximum stated length is not the maximum diameter. (Always work within the stated Safe Work Load) Above values are based on cold-rolled mild steel.

389