Planned Works Toolkit Regional Contracts Delivery Process
Stage 1 Stage 2 Stage 3 Stage 4 Stage 5
Stage 2 – Pre-Construction Phase
• A pproved - If the Construction Phase Plan (CPP) meets the requirements and is deemed adequate for works to progress from a health & safety perspective. The Principal Designer (PD) issues a letter of adequacy to the Surveyor and the Principal Contractor (PC). Please note that if a letter of adequacy has not been received then the project will not be able to commence on site. • The Full CDM Process Map • CDM Policy • Asbestos Policy • HSE – F10 For notifiable Projects Link Link Link Link
The Surveyor should notify F&G at as early as possible of the project using the Proforma for Project Notification. The Principal Designer will compile the Pre-Construction Information (PCI) Pack and issue to the Surveyor and the Principal Contractor. The Principal Contractor is to compile their Construction Phase Plan using the information provided within the Pre-Construction Information Pack and email to anchor@fgould.com. The Principal Designer will conduct a review of the Principal Contractors Construction Phase Plan against the requirements of the CDM 2015 Regulations and advise if its: • N ot Approved - If The Construction Phase Plan does not meet the requirements and is returned to the Principal Contractor for amendments