LIGHTING | FIRE | WATER | AUDIO
STEP 3
FIND TOTAL DYNAMIC HEAD
FIND THE TOTAL DYNAMIC HEAD Add the Friction Head in Feet to the Vertical Head of this feature. Vertical Head is the height in feet from the surface of the water the pump will be sitting in, to the highest point the water is pumped to.
+ = VERTICAL HEAD IN FEET
FRICTION H E A D IN FEET
TDH
STEP 4 CHOOSE YOUR PUMP Locate your Total Dynamic Head at the top of the CHART C (below), follow that column down to find a corresponding cell with the Recommended Flow . Now you have found the right pump(s) with the right Flow at the right TDH!
TOTAL DYNAMIC HEAD HEIGHT
ITEM #
WATTS MAX GPH 5’
10’
15’
20’
25’
30’
35’
40’
1640 2640 3000 4490
1060 350 1760 715 2180 1215
ATL/TT1500 ATL/TT2000 ATL/TT3000 ATL/TT4000 ATL/TT5000 ATL/TT6000 ATL/TT7500 ATL/TT9000 ATL/MD250 ATL/MD350 ATL/MD550 ATL/MD750 ATL/MD1000 ATL/MD1250 ATL/MD1500 OAS/45421 OAS/45422 OAS/45423 OAS/45424 OAS/45425 OAS/45426
101 115 173
475
3330 1785 700 4255 3170 1615 4915 3395 1750
230 310 334 520 587
TT Series
5150
6600
7650 6300 4640 2860 1250
8800 7470 5990 4260 2595 1005
300 370 650 790
65
15
145 385 465 785
25 40 50 90
MD Series
1080 1330 1560 1650 2300
275
1040 580
120 165
1255
780
1200 600
70
1900 1450 780
130 170
3700 3050 2410 1840
Waterfall Pump
5150
4320 3580 2260
230 460 600
6600 5600 4500 3150 8000 6600 5300 3950
N/A 8150 6830 5535 4120 2535 N/A N/A N/A N/A N/A N/A 10200 8280 7560 6780
ATL/A31
1HP 2HP
1160 2055
ATL/AN-32 SHI/2.15S SHI/2.25S SHI/2.4S SHI/2.75S SHI/XP2.75S
3300 2700 1800 900
1/5 HP 1/3 HP 1/2 HP
328 414 567
4800 4000 3000 2100 1200
5700
5100 4320 3420 2750 2000 950
7000 6900 6000 5400 4800 4100 3200 2100 1450
1 HP 1HP
1088 1265
10500 10200 9000 7200 5700 3780 2160
Recommended Operating Range Best Efficiency Range Do Not Operate Range
Full Catalog Available at linzel.ca
105
Made with FlippingBook Ebook Creator