WeldStation Ductless Booths by Clean Air Industries

The WeldStation by Clean Air Industries is the premiere solution used in hundreds of trade schools around the country. Learn more.

WELDSTATION

The WeldStation TM is a ductless fume extraction solution trusted by hundreds of trade schools and welding labs across North America. Engineered for adaptability, the WeldStation is available in single or dual booth configurations, giving you the flexibility to meet your workspace needs. Its ductless design and powerful 4,000 CFM of airflow ensure seamless, heavy-duty performance without the hassle of additional accessories or fume capture arms. Crafted with pride in the USA, the WeldStation features rugged 12-gauge, powder-coated steel construction for unmatched durability. Its self-contained, plug-and-play design streamlines installation, cutting costs and saving valuable time. Simply position the WeldStation, connect power, and you’re ready to weld. No ducts. No delays. Just a smarter, cost- effective solution built for demanding training environments.

sales@clean-air.com

1-866-665-1829

www.clean-air.com

WELDSTATION

Product Benefits • No Ducting Required : Save on expensive start-up costs and valuable space associated with the installation of ducting. The WeldStation is a self- contained system. • Capture Airborne Contaminants At Source : Contains and eliminates harmful weld fumes before they can spread within your facility. • Flexibility : Ducted systems are a fixed solution, making layout changes or facility expansions a costly challenge. The WeldStation offers unmatched flexibility. Its modular design allows you to adapt quickly by repositioning booths or seamlessly adding more as your needs grow. Booths can be installed side-by-side and/or back-to-back. Product Features • Single and dual booth configurations available to address your needs • Built-in tool board • Integrated weld curtain locks in with a button pin • Simple filter replacement featuring our new cam lock design • Knock out holes for electrical needs • VFD Standard for increased energy savings, noise reduction, and motor speed control • Two 1” pulsing valves – auto or manual • 1” NPT compressed air connection – 70-90 PSI required

Optional Features • Bar-grated table • Small and large part bins • Welder shelf • Hooks • Customizable logo

Filter Information • Two-Stage Spark Arrestors : Two 24” x 24” x 2” Metal Spark Baffle Filters and two 24” x 24” x 2” Metal Mesh Filters • Filter Cartridges : Four Fire Retardant filters with 226 ft 2 of media (904 ft 2 total) – also available in High Efficiency Nanofiber

sales@clean-air.com

1-866-665-1829

www.clean-air.com

Key Applications • Manual Welding • Grinding • Deburring

Health & Safety Exposure to weld fumes and weld smoke can pose various health risks. The specific health effects depend on the composition of the fumes, the duration and intensity of exposure, and individual susceptibility. Here are some potential health risks associated with exposure to weld fumes and weld smoke:

• Respiratory Issues • Lung Damage • Metal Fume Fever • Neurological Effects

Warranty Information All Clean Air Industries units are backed by a standard 10-year manufacturer’s warranty* We guarantee that the major structural components of the goods will be free from defects in material and workmanship for ten (10) years from the date of shipment. *This warranty does not cover consumable parts, fuses, filters, or other non-structural components. For warranty details, visit our website: https://clean-air.com/warranty Regulatory Compliance Health and safety issues are being taken very seriously by a growing number of companies as OSHA, International, and industry standards increase. Many large us manufacturers are planning and adopting European exposure limits as a global standard for their entire company and are exceeding OSHA Standards. To meet these standards companies must implement a highly efficient dust and fume filtration system to filter out the harmful particulate. The exposure limits these companies are targeting range from .02 - l mg/m3 depending on company policy, well below the 5 mg/m3 standard set by OSHA.

sales@clean-air.com

1-866-665-1829

www.clean-air.com

WELDSTATION Technical Specifications

PRE-FILTERS Two-Stage Spark Arrestors 2x Metal Baffle Filter : 24” x 24” x 2” (Part #: FIL-WS-BAFFLE) 2x Metal Mesh Filter : 24” x 24” x 2” (Part #: FIL-WS-METALMESH)

MAIN FILTER CARTRIDGES 4x 80/20 FR – MERV 11 (Part #: FIL-WS-1834) • Length: 26” • Outside Diameter: 12.75” • Inside Diameter: 8.37" Nanofiber upgrade available (Part #: FIL-WS-NANO)

USER & MAINTENANCE MANUAL To learn how to properly operate and maintain this unit, scan the QR code to instantly access your user and maintenance manual.

Contact us for replacement filters and parts, or service.

MODEL

CFM

MOTOR

VOLTAGE

MAX NOISE

DIMENSIONS

WEIGHT

WeldStation Single 5’ WeldStation Single 6’

4000 5HP@3400 RPM 208, 240, 460v/3/60Hz 4000 5HP@3400 RPM 208, 240, 460v/3/60Hz

74 dBA 74 dBA 74 dBA 74 dBA

59” W x 122” H x 71” D 1600 lbs. 71” W x 122” H x 71” D 1650 lbs. 118” W x 122” H x 71” D 2100 lbs. 142” W x 122” H x 71” D 2200 lbs.

WeldStation Dual 5x5 4000 5HP@3400 RPM 208, 240, 460v/3/60Hz WeldStation Dual 6x5 4000 5HP@3400 RPM 208, 240, 460v/3/60Hz

* Please note that the dimensions provided are based on our base models and may vary depending on selected features. To ensure accurate shipping quotes, kindly contact us for personalized information that considers your chosen product features and customizations. Feel free to reach out with any questions or to request a personalized shipping quote. We are committed to your satisfaction and look forward to helping you!

(Manufacturing) 127 Franklin Rd Russellville, KY 42276

(Head Office & Manufacturing) 7 Superior Drive Rome, GA 30161

sales@clean-air.com

1-866-665-1829

www.clean-air.com