Electricity and Control August 2024

ENERGY MANAGEMENT + THE INDUSTRIAL ENVIRONMENT : PRODUCTS + SERVICES

Cost savings with power factor correction

Ged Hebdige, Technical Director at UK company Powerdown220, a specialist in voltage optimisation, highlights two technologies for instant energy savings.

This UPS model features the Eaton ABM+ Advanced Battery Management technology, which extends battery life by up to 50% and allows for accurate battery life pre- diction and timely replacement alerts powered by machine learning. Additionally, it is supplied with hot-swappable batteries and an intuitive battery replacement wizard ac- cessed via a built-in graphic LCD (liquid crystal display). Eaton’s Intelligent Power Manager (IPM2) and Dis- tributed IT Performance Management (DITPM) software enable remote monitoring and management of IT infra- structure, even in hard-to-reach locations, including se- cure device configuration and firmware updates. According to Jessica Masina, Field Product Marketing Manager at Eaton Africa, “The new Eaton 5P Gen 2 UPS offers superior output, security, and control compared to other devices in its category.” The Eaton 5P Gen 2 UPS, together with the cybersecure Gigabit Network Card (in- cluded in the Netpack versions), meets strict cyberse- curity standards. Moreover, Eaton’s Brightlayer Software Suite is available for seamless integration with virtualis- ation environments, ensuring continuous service and data integrity. Customers can opt for the compact 1U rack or the tower option, the Eaton 5P Gen 2 UPS fits all space re- quirements, so it is compatible with a variety of setups. □ Power factor correction (PFC) minimises the amount of apparent power the transmission system must gener- ate by supplying the required amount of reactive pow- er locally, avoiding unnecessary power generation and distribution losses. PFC can cut electricity bills, improve equipment lifespan and in some cases, obviate the need to increase the supply availability or save the costs of uprating or installing a new supply. Voltage optimisation (VO) technology can, in some cases, provide further savings. VO reduces the incoming mains supply voltage to the level the equipment is de- signed to work with. This extends its lifespan, cuts elec- tricity bills by around eight per cent and helps reduce the company’s carbon footprint. □ draw heavy loads in a range of applications, such as fans and conveyors. Suppliers bill consumers for active power, not reactive power. However, they must still supply enough reactive power to meet a user’s demand. A power factor of 50% means the supplier must provide twice as much pow- er as they charge for, and electricity suppliers may then charge users penalties if their power factor is poor. Low power factor can also make it harder for a busi- ness to expand operations, because the existing supply might not be adequate to cope with current demand plus the extra to make up for the low power factor. Hebdige adds that power factor is also an important part of power quality which can affect the lifespan of electrical equipment.

Hebdige explains that the ‘apparent power’ supplied through the mains by the electricity provider is made up of active power plus reactive power. Active power is usually referred to as ‘real power’ and is expressed as Watts (W) or kilowatts (kW). This is the electrical energy that is con- verted into work, turning the shaft of a motor, for example, and it’s what the supplier bills the user for in kWh. Reactive power, on the other hand, is used to gener- ate and maintain the magnetic fields surrounding equip- ment such as motors and transformers. The equipment needs the reactive power to function, but it does not di- rectly go to doing useful work. Power factor is the ratio of active power to reactive power. The more reactive power a facility needs, the low- er its power factor. The benchmark is a power factor of 95%, with most users above 80%. However, power factor can be as low as 50%, which means only half of the pow- er supplied goes into active work. Facilities employing many inductive loads that rely on magnetic fields to operate are most likely to have a re- duced power factor. Inductive loads tend to draw current that is out of sync with the voltage, resulting in a lagging power factor. This is most common with industrial and commercial consumers, where motors and transformers

Power factor correction and voltage

optimisation can enable savings on energy costs.

Secure power for IT environments

Although Eskom has sustained a stable power supply nationally through more than 100 consecutive days with- out loadshedding, the implementation of load reduction by the national and municipal utilities still raises an op- erational barrier to many businesses. Consequently, demand for backup power continues to grow, to keep critical IT appliances running in the event of an outage. Power management company Eaton has recently launched the Eaton 5P Gen 2 UPS, a compact and ef- ficient power solution for edge and informational tech- nology (IT) needs. Reportedly, delivering more output, security and control than any other devices in this class, the new product range also enables fleet management, remote UPS setting and remote firmware upgrades. The 5P Gen 2 has enhanced power capability and provides up to 1 350 W, which is 22% more than its pre- decessor and 33% more than comparable models available on the market, making it suitable for pro- tecting a wide range of applications. Intelligent design ensures its stable performance and energy

Eaton has launched the new 5P Gen 2 UPS to protect critical IT appliances against power outages.

savings, and advanced load segment control prioritises critical equipment and optimises battery runtime.

14 Electricity + Control AUGUST 2024

Made with FlippingBook Online newsletter maker