ElQuator Hydro Power

• Below is the calculation to represent the 1MW power requires. It shows 1.3MW produced whereby 22% to 28% is used for the pumps to function in pumping the water back to the top reservoirs.

Micro Hydro System Calculation

Total output

kW

1,300

Water consumption Water consumption

l/sMW l/hMW

529

1,904,400 2,475,720

Total water consumption

l/h

Calculation of Pipe Cross Section

D Q

1.25dm

27 l/s

q

1.23dm2

v

2.17m/s <3m/s

Made with FlippingBook - professional solution for displaying marketing and sales documents online