Commander C - Simple, Reliable Motor Control

WWW.CONTROLTECHNIQUES.COM

Mounting & Environment

IP20 Conduit Box ULType 1 ingress protection (available as an accessory)

IP Rating

Storage Temperature

-40 °C to 60 °C (-4 °F to 140 °F) -20 °C to 40 °C (-4 °F to 104 °F)

Operating TemperatureWithout De-Rate

-20 °C to 60 °C (-4 °F to 140 °F) Frames 1 to 4 -20 °C to 55 °C (-4 °F to 131 °F) Frames 5 to 9

Operating Temperaturewith De-Rate

Cooling Altitude Humidity Pollution

Integral cooling fan

≤3000 m(≤1000 m no de-rate; 1000 m to 3000 m derate 1 % every 100 m)

95 % non-condensing at 40 °C / 104 °F - EN61800-2(3k3) Pollution degree 2 - dry, non-conducting pollution only

Reference standard IEC60068-2-27, IEC60068-2-29 bump test, IEC60068-2-64 randomvibration test, IEC60068-2-6, EN61800-5-1 sinusoidal vibration test. Tested to Environmental Category ENV3

Vibration

Mechanical Shock

Tested in accordancewith IEC 60068-2-27 and IEC 60068-2-29

Frame 1 to 4 – Surface mount via mounting holes or DIN Rail mount Frame 5 to 9 – Surface mount via mounting brackets or through-panel mount via through-panel mounting kit

Mounting Methods

Mounting Clearance Overvoltage Category Corrosive Environments

0 mm either side, 100 mm above and below Category III (IEC/EN/KN/UL61800-5-1)

EN 60721-3-3 ISO9223 Class C3

MaximumMotor Cable Length

75 m Frame 1 | 100 m Frames 2 to 4 | 200 m Frames 5 to 6 | 250 m Frames 7 to 9

Standards Approvals

CE (European Union), cUL Listed (USA and Canada), DNV (marine applications), KC (Korea), RCM (Australia/ New Zealand), EAC (Russian Customs Union), UKCA (United Kingdom), C-Tick (Australia)

E171230

Product Safety Standards

IEC/EN/KN/UL 61800-5-1, CSA C22.2 No.274, GB12668.501-2013

C300 models only: The Safe Torque Off (STO) function may be used as a safety component of a machine. Type examination certificates by TÜV Rheinland:

Frame sizes 1 - 4: No. 01/205/5383.03/18 Frame sizes 5 - 9: No. 01/205/5387.02/18 Functional safety parameters: EN ISO 13849-1 - Cat 4, PLe EN61800-5-2/EN62061/IEC 61508 - SIL3 UL functional safety approval: FSPC E171230

TÜV

IEC/ EN 61800-3 Immunity and Emissions EN 61000-6-2: Immunity for industrial environments EN 61000-6-4: Emissions for industrial environments

Product EMC Standards

EN 61000-3-2: Harmonic current emissions An EMC data sheet is available on request

RoHS

Complies with the Restriction of Hazardous Substances Directive (2011/65/EU)

Immunity Compliance

Second environment (Industrial)

ISO

Manufacturing facilities comply with ISO 9001:2015 and ISO 14001

Warranty Warranty

5Years (warranty terms and conditions apply)

Accessories Remote Interfaces Filters & Cables

Remote keypad IP66, Remote keypad RTC, HMI External EMC filters, CT communications cable

Communication & Feedback, SI-Options

AI-485 24 VAdaptor, SI-EtherCAT, SI-PROFIBUS, SI-Ethernet , SI-DeviceNET, SI-CANopen, SI-PROFINET , SI-POWERLINK, SI-Encoder

Back-up & Cloning

AI-Back-up Adaptor &AI-Smart Adaptor

Conduit Box

For ULType 1 ingress protection

Protection Conformal Coating DC Bus Undervoltage Error Level

100 V models: 175 Vdc | 200 V models: 175 Vdc | 400 V models: 330 Vdc | 575 V models: 435 Vdc | 690 V models: 435 Vdc Frame sizes 1 - 4: 100 V models: 510 Vdc | 200 V models: 510 Vdc | 400V models: 870 Vdc Frame size 5 - 9: 200V models: 415 Vdc | 400 V models: 830 Vdc | 575 V models: 990 Vdc | 690 V models: 1190 Vdc

DC Bus Overvoltage Error Level

Drive Overload Error

Programmable: Default settings: 180% for 3s, 150% for 60s

Instantaneous Overcurrent Error/Limit

220% of rated motor current

Phase Loss Error

DC Bus Ripple Threshold Exceeded

Overtemperature Error

Control Board Over Temperature, Inverter Model Temperature, Inverter Thermistor Temperature,Drive heatsink temperature exceeds 95°C (203°F)

Short Circuit Error Ground Fault Error

Protection against output phase-to-phase fault Protection against output phase-to-ground fault

Motor Thermal Protection

Electronically protects the motor from over-heating due to loading conditions Parameter set to avoid errors and machine downtime (needs to be configured)

Keep Running

Dedicated Thermistor Input General Items suppliedwith the drive

Avoid downtime or machine damage due to overheated motor

Step-By-Step Guide, Safety Information,Grounding bracket (Frames 1 to 4), Surface mounting brackets (frame 5 to 9)

15