Commander C - Simple, Reliable Motor Control

Commander C combines efficiency and reliability to offer optimum performance for a wide range of applications.

COMMANDER C AC DRIVES, GENERAL PURPOSE FLEXIBILITY FOR COUNTLESS APPLICATIONS

WWW.CONTROLTECHNIQUES.COM

THE 6TH GENERATION OF EXCELLENCE IN MOTOR CONTROL

COMMANDER C 0.25 kW to 132 kW (0.33 hp to 200 hp)

Linear V to F, Square V to F, Dynamic V to F, Set Point V to F, Stator Resistance Compensation, RFC-A (enhanced open-loop performance)

Commander C combines efficiency and reliability to offer optimum performance for a wide range of applications. With 9 frame sizes, it covers powers from0.25 to 132 kW / 0.33 to 200 hp. Essential features are built in, including PLC capabilities for simple programming needs, dual STO safety function (C300 variants only), braking transistor and PID control.

Free 5 year warranty* Our Commander C series is built to copewith harsh environments. In fact, it is so reliable we are confident enough to supply it with a free five-year warranty.

Nowyou can buywith the same confidence.

*Warranty terms and conditions apply.

2

WWW.CONTROLTECHNIQUES.COM

THE ULTIMATE ALL-IN-ONE DRIVE KEY BENEFITS Adaptable to your application Whether you have a single application or a variety of different ones, Commander C fits right in.With all essential features built-in, it's ready to go right out of the box. Integrated functional safety The Dual Safe Torque Off (STO) feature, certified to the highest level of machine safety, SIL3/PLe, and compliant to EN/IEC 61800-5-2, prevents the motor from moving unexpectedly, protecting both equipment and operators. On-board PLC The generous 30kBuser space allows for add-on programmable functions,more elaborate I/O features and special software that enables greater machine control. The on-board PLC also eliminates the need for an external controller, saving both on cost and space. Compact design Commander C is one of the most compact drives within its category, taking little space in the cabinet and minimizing installation cost. Super quick start-up To get started you only need to set-up 4 parameters (motor rated current, RPM, voltage and power) and for your convenience we've listed them on the front cover of the drive. Flexible connectivity The plug in communication modules enable integration with the most common industrial fieldbuses. Worldwide availability and outstanding service Need expert advice and support? Wherever you are in the world we've got you covered via our sales offices or Control Techniques approved distributors.

3

WWW.CONTROLTECHNIQUES.COM

CASE STUDY: GIVING BACK TO

NATURE AT SINGAPORE BOTANICAL GARDENS

4

WWW.CONTROLTECHNIQUES.COM

COMMANDER C DRIVES SAVE ENERGY

Established in 2012,Success Electric Pte Ltd specialises inmanufacturing low-voltage switchgear and control gear assemblies for diverse market sectors in Singapore and numerous global projects. The company’s electrical power distributionsolutions range frommainswitchboards(MSB) todistribution boards (DB). It also provides motor control and automation panels for air conditioning & mechanical ventilation (ACMV) systems, plumbing & sanitary, fire pump, refuse chute, and machinery control systems.

The Challenge

Singapore Botanic Gardens is the first and only tropical botanic garden on the UNESCOWorld Heritage List. Its newGallop Extension is eight hectares of framed landscapes composed of native plants and forests, contributing to the gardens’ rich heritage and its role in research, conservation, education, and recreation. As a natural extension of the gardens’ nature area, it covers the rain forest and the learning forest, educating visitors on forest ecology and conservation significance.

With a new addition to the visitor attraction, the Botanical Gardens required an irrigation booster pump system to supply water to the entire Gallop Extension field of plants and forests. On winning the contract, Success Electric set about the mission to find the right drive for the job.

The Benefit

The Solution

Control Techniques’ Commander C drives are integrated into Success Electric’s irrigation booster pump system controller. Commander C controls and regulates the pumps to distribute the water supply to the entire field of native plants and forests at programmed times of the day and night, keeping the plants watered while saving energy and natural resources. Commander C provides a low starting current while ramping up to full speed at 50Hz, thus reducing the overall energy consumption. The easy-to-use LED keypad and a parameter guide on the front of the drive allow the gardens’ maintenance team to modify the pressure settings for the pump sets.

“The solution has reinforced the energy saving benefits that variable speed drives deliver. In this case, Singapore Botanical Gardens is making energy savings of 30%. With the compact and programmable Commander C drives,wewere able to reduce the panel footprint, leaving more space for nature that visitors can enjoy.”

AnthonyYeo Success Electric Business Manager

5

WWW.CONTROLTECHNIQUES.COM

CASE STUDY: SIMPLIFYING SYSTEM DESIGN AT SCHULTHESS

6

WWW.CONTROLTECHNIQUES.COM

COMMANDER C DRIVES WITH BUILT-IN LAUNDRY FEATURES Schulthess is the leading Swiss supplier of washing equipment. Ever since its inception in 1845, durability and performance have been at the core of the solutions designed and built by the company. The Schulthess laundry equipment is easy to operate, economical to use and boasts excellent process reliability. Each machine has been tested for 30,000 cycles – equivalent to a lifetime of 20 years. The company is constantly investing in research and development,which has helped to secure only the highest grade materials and processes for durable and environmentally-friendly products. The Challenge As they've embarked on a new product development, the Schulthess team has been on the lookout for an inverter drive supplier that can meet their demands for quality and performance, while also offering a technological advantage and satisfying the regulatory requirements. Inverter drives are crucial components in the design of the laundry solution as proprietary inverter drive technology provides smooth, reliable power for better wash and extraction, reduces energy and water consumption and improves the customer experience.

The Solution

The Benefit

The Swiss and UK team at Control Techniques have worked closely with Schulthess’ R&D department to provide the best match to their needs. Commander C, with the built-in laundry specific software, proved to be the right solution. Commander C can detect imbalances caused by laundry becoming tangled into large lumps and initiate a tumbling sequence to untangle the load. Thanks to this feature the wash cycle is much smoother and the machine life is extended as there’s less stress to the mechanical parts. The on-board PLC has allowed the joint teams to further expand the laundry specific capabilities while also reducing the size of the installation as an external controller was no longer required. Commander C is built to cope with harsh environments and we are confident in its durability to supply it with a free 5 year warranty. This has been a valued benefit to guarantee the quality of the Schulthess machinery.

“Since switching to Commander C, we have been able to simplify the system design. For example, we no longer need an imbalance sensor. Imbalance detection and broken belt detection are all built-in thePLC.Commander C’smotor control performance is outstanding, and it has greatly improved our testability and troubleshooting compared to the previous drive. Throughout this project, we have had excellent support from the Control Technique teams in the UK and Switzerland and it’s been a great working partnership. We will most certainly use Control Techniques’ inverters for our future projects.”

Mr.Remo Bucher Engineering Manager

7

WWW.CONTROLTECHNIQUES.COM

COMMANDER C DRIVES AT THE HEART OF GENERAL PURPOSE APPLICATIONS WORLDWIDE

Conveyors

• Reliable speed control with fieldbus communications • S-ramp acceleration / deceleration profiling provides smooth speed transitions minimizing machine jerk • Overload capacity up to 180%for rapid acceleration or load changes • Built-in STO function ensures operator safety by preventing the motor frommoving unexpectedly

Access Control

• Smooth motionwith enhanced open loop control • Compact physical size allows the drive to be mounted easily in small control cabinets • Highly reliable in harsh environments, providing long lasting service

Lifts, Hoists,Winches

• Adjustable mechanical brake sequencing with torque proving function – no need for an external controller • Embedded PLC functionality can manage local I/O reducing the need for an external controller

8

WWW.CONTROLTECHNIQUES.COM

Process (Mixers, Crushers,Agitators, Centrifuges, Extruders)

• Ease of integration to external PLC or other management systems through powerful networking options • Conformal coating for enhanced environmental protection

• Overload capacity up to 180% • Highly stable motor control

Pumps, Fans, Compressors

• Improved energy efficiency during periods of low demand • On board PLC & PID functionalities make advanced control easy and efficient without the need of an external controller • Skip Frequencies allow users to easily avoid equipment resonant frequencies, reducing high vibration levels • Supply Loss Ride Through will keep the drive up and running through most power outages

9

WWW.CONTROLTECHNIQUES.COM

COMMANDER C KEY FEATURES

Easy motor pairing and performance control

V/Hz by default for easy set-up

Enhanced open loop Rotor Flux Control • Closed current loop for greater stability • Auto tuning

• Slip compensation • Multi-motor control • 100% torque available to 1 Hz

(stationary and rotating)

• Square lawV/F mode • Dynamic V/F mode • Auto tune

(stationary and rotating)

Flexible connectivity The SI Interface on Commander C enables integration with a wide range of industry standard fieldbuses to allow remote control and diagnostics across different networks. Additionally, the AI-485 Adaptor option permits connection to RS485 networks using Modbus RTU.

10

WWW.CONTROLTECHNIQUES.COM

Embedded intelligence reduces costs

Robust and reliable design

Onboard PLC

• PCBs conformal coated for resilience to harsh environments • Patented air flow system cools and protects components • Supply voltage tolerance for smooth operation during disturbances to supply • Intelligent three speed user replaceable fan with failure detection • Trip avoidance features take action instead of tripping out: i. Load shedding reduces speed at current limits ii. Supply loss ride-through keeps motor running during brown outs • High overload capability: 180% for 3 seconds (RFC-A mode) or 150% for 60 seconds (Open loop mode) • IP20 ingress protection as standard and conduit box UL Type 1 available as an accessory

Built-in independent PID control

Energy saving

• Dynamic V/Hz - improves efficiency by reducing motor losses during low demand • 98% efficient - only 2% of energy is lost during the conversion process • Low power standby mode - drives can be idle for significant periods, saving energy • Automatic 3-speed cooling fan - keeps energy usage & acoustics noise to a minimum by intelligently responding to load and the environment • Square Law V/F mode - optimized for quadratic loads to reduce motor losses

Input / Output

Onboard as standard • 3 x Analog I/O • 5 x Digital I/O • 1 x Relay • 2 X STO (C300 only)

SI-I/O • 4 x Digital I/O • 1 x Digital input • 3 x Analog inputs (default) / Digital inputs • 2 x Relays

11

WWW.CONTROLTECHNIQUES.COM

COMMANDER C INTUITIVE SOFTWARE

Intuitive commissioning software For fast task based commissioning and easy maintenance, Connect offers a familiar Windows™ interface and intuitive graphical tools to enhance data analysis. The dynamic drive logic diagrams allow the visualisation and control of the drive in real time. The parameter browser enables viewing, editing and saving of parameters as well as importing parameter files from our legacy drives.

Advanced machine control For more advanced applications, Machine Control Studio provides a flexible and intuitive environment for programming. This is possible thanks to the onboard PLC that increases the drives functionality at no extra cost. Control Techniques also provides support for customers’ own function block libraries, with on-line monitoring of program variables with user defined watch windows and help for on-line change of program, in line with current PLC practice.

Machine Control Studio Software

Connect Software

Free to download: www.controltechniques.com/commander-c-setup

12

WWW.CONTROLTECHNIQUES.COM

COMMANDER C VIRTUAL DEMO TOOL

The Commander C Virtual Demo Tool provides a safe and accessible first experience with Commander C variable speed drives and allows you to get familiar with its keypad and menu structure. This digital replica of a Commander Cdrive,motor and control allowsyou to use thevirtual keypad to set-up the drive parameters for commissioning just like in a real situation. Once the key parameters have been set, the drive can be enabled and the motor shaft will spin.

To see just how easy it is to set-up the drive, visit: www.controltechniques.com/vitual-demo-tool

Drive Enable

Frequency reference 2

Run Forward

Analog Meter

FREQUENCY

Run Reverse

Analog input select

Frequency reference 1

Diagnostics? There’s an app for that

Free online help: Drive-Setup.com

Diagnostic Tool App The Diagnostic Tool App is a fast and simple tool,which allows users to quickly solve any error codes that the drive may show. Download from: controltechniques.com/mobile-applications

You’ll have permanent free access to lots of web pages with useful information, like user manuals, ‘how-to’ videos and guides. YouTube Training Access a series of Commander C training videos,available onYouTube, visit: www. youtube.com/controltechniques

FREE DOWNLOAD

13

WWW.CONTROLTECHNIQUES.COM

COMMANDER C SPECIFICATIONS

Power & Control

100 V drive: 100 V to 120 V ±10 % 200 V drive: 200 V to 240 V ±10 % 400 V drive: 380 V to 480 V ±10 % 575 V drive: 500 V to 575 V ±10 % 690 V drive: 500 V to 690 V ±10 % Maximum supply imbalance: 2 % negative phase sequence (equivalent to 3 % voltage imbalance between phases)

Supply Requirements

Input Displacement Power Factor

0.97

Phase

1 and 3 (model dependent)

Power Range

0.25 to 132 kW / 0.33 to 200 hp

Input Frequency Range

45 to 66 Hz

Output Frequency/Speed Range

0 to 550 Hz

Size 1 - 4: 0.667, 1, 2, 3, 4, 6, 8 12 & 16 kHz Size 5 - 9: 2, 3, 4, 6, 8 12 & 16 kHz (Factory default = 3kHz)

Switching Frequency

Heavy Duty Overload Capability

150 % for 60 s (open loop mode), 180 % for 3 s (RFC-A mode)

Linear V to F Square V to F

Dynamic V to F Set Point V to F Stator Resistance Compensation RFC-A (enhanced open-loop performance)

Operating Modes

Coast, Ramp, Ramp & DC Injection Braking, DC Injection Braking with 0 Hz detect, Timed DC Injection Braking, Built-in braking transistor, external resistor required

Stopping Modes

Communication & Interfaces

Modbus RTU EtherCAT PROFIBUS Ethernet DeviceNET

Communications

CANopen PROFINET POWERLINK (all available with AI/SI-options)

Fixed LED keypad Remote IP66 Keypad (available as an accessory) Remote RTC Keypad (available as an accessory) HMI (available as an accessory) Connect (PC commissioning & cloning tool) Machine Control Studio for on-board PLC programming

Keypads

User Software Tools (Free To Download)

Inputs & Outputs

2 x Analogue input Possible settings: 0-10 V, 0-20 mA, 4-20 mA (No Alarm), 4-20 mA (Alarm), 4-20 mA (Error) 1 x Analogue output Possible settings: 0-10 V

Analogue

3 x Digital inputs (1 frequency input) 1 x Digital input / output programmable 1 x Digital input / output programmable (can be used as a frequency or PWM output to represent analogue value)

Digital

Digital Input Logic

Positive

Relay

1 x Relay (single pole, relay)

Accuracy

Frequency 0.02%,Analogue input 1: 11 bit plus sign,Analogue input 2: 11 bit. Current typical 2%.

3 x Analogue inputs (default) / Digital inputs programmable 4 x Digital input / output programmable 1 x Digital input 2 x Relays

Extra I/Owith SI-I/O Option Module (Available as an Accessory)

14

WWW.CONTROLTECHNIQUES.COM

Mounting & Environment

IP20 Conduit Box ULType 1 ingress protection (available as an accessory)

IP Rating

Storage Temperature

-40 °C to 60 °C (-4 °F to 140 °F) -20 °C to 40 °C (-4 °F to 104 °F)

Operating TemperatureWithout De-Rate

-20 °C to 60 °C (-4 °F to 140 °F) Frames 1 to 4 -20 °C to 55 °C (-4 °F to 131 °F) Frames 5 to 9

Operating Temperaturewith De-Rate

Cooling Altitude Humidity Pollution

Integral cooling fan

≤3000 m(≤1000 m no de-rate; 1000 m to 3000 m derate 1 % every 100 m)

95 % non-condensing at 40 °C / 104 °F - EN61800-2(3k3) Pollution degree 2 - dry, non-conducting pollution only

Reference standard IEC60068-2-27, IEC60068-2-29 bump test, IEC60068-2-64 randomvibration test, IEC60068-2-6, EN61800-5-1 sinusoidal vibration test. Tested to Environmental Category ENV3

Vibration

Mechanical Shock

Tested in accordancewith IEC 60068-2-27 and IEC 60068-2-29

Frame 1 to 4 – Surface mount via mounting holes or DIN Rail mount Frame 5 to 9 – Surface mount via mounting brackets or through-panel mount via through-panel mounting kit

Mounting Methods

Mounting Clearance Overvoltage Category Corrosive Environments

0 mm either side, 100 mm above and below Category III (IEC/EN/KN/UL61800-5-1)

EN 60721-3-3 ISO9223 Class C3

MaximumMotor Cable Length

75 m Frame 1 | 100 m Frames 2 to 4 | 200 m Frames 5 to 6 | 250 m Frames 7 to 9

Standards Approvals

CE (European Union), cUL Listed (USA and Canada), DNV (marine applications), KC (Korea), RCM (Australia/ New Zealand), EAC (Russian Customs Union), UKCA (United Kingdom), C-Tick (Australia)

E171230

Product Safety Standards

IEC/EN/KN/UL 61800-5-1, CSA C22.2 No.274, GB12668.501-2013

C300 models only: The Safe Torque Off (STO) function may be used as a safety component of a machine. Type examination certificates by TÜV Rheinland:

Frame sizes 1 - 4: No. 01/205/5383.03/18 Frame sizes 5 - 9: No. 01/205/5387.02/18 Functional safety parameters: EN ISO 13849-1 - Cat 4, PLe EN61800-5-2/EN62061/IEC 61508 - SIL3 UL functional safety approval: FSPC E171230

TÜV

IEC/ EN 61800-3 Immunity and Emissions EN 61000-6-2: Immunity for industrial environments EN 61000-6-4: Emissions for industrial environments

Product EMC Standards

EN 61000-3-2: Harmonic current emissions An EMC data sheet is available on request

RoHS

Complies with the Restriction of Hazardous Substances Directive (2011/65/EU)

Immunity Compliance

Second environment (Industrial)

ISO

Manufacturing facilities comply with ISO 9001:2015 and ISO 14001

Warranty Warranty

5Years (warranty terms and conditions apply)

Accessories Remote Interfaces Filters & Cables

Remote keypad IP66, Remote keypad RTC, HMI External EMC filters, CT communications cable

Communication & Feedback, SI-Options

AI-485 24 VAdaptor, SI-EtherCAT, SI-PROFIBUS, SI-Ethernet , SI-DeviceNET, SI-CANopen, SI-PROFINET , SI-POWERLINK, SI-Encoder

Back-up & Cloning

AI-Back-up Adaptor &AI-Smart Adaptor

Conduit Box

For ULType 1 ingress protection

Protection Conformal Coating DC Bus Undervoltage Error Level

100 V models: 175 Vdc | 200 V models: 175 Vdc | 400 V models: 330 Vdc | 575 V models: 435 Vdc | 690 V models: 435 Vdc Frame sizes 1 - 4: 100 V models: 510 Vdc | 200 V models: 510 Vdc | 400V models: 870 Vdc Frame size 5 - 9: 200V models: 415 Vdc | 400 V models: 830 Vdc | 575 V models: 990 Vdc | 690 V models: 1190 Vdc

DC Bus Overvoltage Error Level

Drive Overload Error

Programmable: Default settings: 180% for 3s, 150% for 60s

Instantaneous Overcurrent Error/Limit

220% of rated motor current

Phase Loss Error

DC Bus Ripple Threshold Exceeded

Overtemperature Error

Control Board Over Temperature, Inverter Model Temperature, Inverter Thermistor Temperature,Drive heatsink temperature exceeds 95°C (203°F)

Short Circuit Error Ground Fault Error

Protection against output phase-to-phase fault Protection against output phase-to-ground fault

Motor Thermal Protection

Electronically protects the motor from over-heating due to loading conditions Parameter set to avoid errors and machine downtime (needs to be configured)

Keep Running

Dedicated Thermistor Input General Items suppliedwith the drive

Avoid downtime or machine damage due to overheated motor

Step-By-Step Guide, Safety Information,Grounding bracket (Frames 1 to 4), Surface mounting brackets (frame 5 to 9)

15

WWW.CONTROLTECHNIQUES.COM

COMMANDER C FUNCTIONALITY

Modbus RTU Communications (available with AI-485 Adaptor)

ControlWord Control

Cloning

Serial Baud Rate

600 to 115000 bps

Modbus RTU Protocol

8.2NP, 8.1NP, 8.1EP, 8.1OP

On Board PLC User Memory Space

30 KB

Machine Control Studio

CODESYS based

User Software Tools (Free to Download)

• Included programming languages: ladder diagram, structure text, function block diagram, instruction list, sequential function chart, continuous function chart • Function block libraries • On-line monitoring of programvariableswith user definedwatchwindows • Support for on-line change of program

Pre-set Programs (Available on Request)

Unbalanced Load Detection (Laundry Application)

Reference Selectable References

4 (Selectable: Analogue Ref. 1,Analogue Ref. 2,Pre-set Frequency Ref., Keypad Ref.)

Jog Reference Up / Down %Reference (Motorised Pot) Bi-Polar Reference Pre-set Speeds

8

Pre-set Timer Skip Frequencies

3

Skip Frequencies Dead Band Local/Remote S-Ramp Acceleration Rates

8

Deceleration Rates

8

Frequency Input Reference (Pulse Train)

0 Hz to 100 kHz

Run Reverse Torque Reference Application Specific PID Controller PID Feedforward PID Threshold Detector PID Slew Rate

PI Control

Reference Configuration Run/Stop Configuration Input Scaling Run Permit (Latching Run) Limit Switches Additional Application Parameters

64

16

WWW.CONTROLTECHNIQUES.COM

Control

Control Mode: Linear V to F

(Definable Boost)

Control Mode: Square V to F

(Definable Boost)

Control Mode: Low Energy Mode (Dynamic V to F) Control Mode: Set Point V to F Control Mode: Stator Resistance Compensation Control Mode: RFC-A (Enhanced Open-Loop Performance) Motor Stability Optimiser

Slip Compensation Auto-tune: Static Auto-tune: Rotating Switching Frequency

Size 1 - 4: 0.667, 1, 2, 3, 4, 6, 8 12 & 16 kHz

Size 5 - 9: 2, 3, 4, 6, 8 12 & 16 kHz

(Factory default = 3kHz)

Catch an Already Spinning Motor Speed Feedback via SI-Encoder Option Second Motor Set-up Motor Pre-Heat Control

Stop Mode: Ramp Stop Mode: Coast Stop Mode: Ramp & DC Injection Stop Mode: DC Injection Brakingwith 0 Hz detect Stop Mode: Timed DC Injection Braking Built-in Braking Transistor (External Resistor Required) Brake Settings (DC bus) Programmable Braking in RFC-A Mode Mechanical Brake Controller

Supply Loss Detection Low DC Link Operation Analogue Input Control Analogue Output Control Digital Input Control Digital Output Control Relay Control

Logic Function Control Timer Function Control Limit Switch Control Variable Selector Temperature Monitoring Keypad Button Assignment Programmable Output Current Limit General Diagnostics Error History Log

10

Auto-Reset After Error Error Time Stamping Power Loss Ride Through Run Time Log Cloning

Via: Modbus RTU, SD Card, Connect

Energy Meter Security

4-digit PIN protection

17

WWW.CONTROLTECHNIQUES.COM

COMMANDER C TERMINAL DIAGRAM

Power Connections

Control Connections OV Common

L1 L2/N

5 1 2 4

L1 L2 L3

Analog Input 1 (Frequency Ref 1)

+10 VDC User Supply

Analog/Digital Input (Frequency Ref 2)

14 12 13 7 9 10 11

Analog Output (Frequency Output)

1Ø only drives

1Ø/3Ø drives

– * + BR

+24 VDC User Supply

Common DC Bus Connections Optional Braking Resistor

Digital Input/Output 1 (Zero Frequency)

Digital Input 2 (Drive Enable)*

Digital Input 3 (Run Forward)

Digital Input 4 (Run Reverse)

Digital Input 5 (Analog 1/1 Select)

34 (31)** 33 (32)** 32 (36)** 31 (35)**

STO 2 (User Enable 2)

0V (STO 2)

C300 ONLY

0V (STO 1)

STO1 (User Enable 1)

Programmable Analog/Digital

51 52 41 42

Status Relay

Safety Relay 24V PSU

_

+

(Drive OK)

Programmable Analog

0V common

+24 VDC External Supply

Programmable Digital

Non-Programmable

18

WWW.CONTROLTECHNIQUES.COM

Pin# Default Function

Type/Description

Notes

1

0V Common

Common for external analog signals

2

Frequency reference 1

Single ended analog input 11 bit

0 to +10 Vdc, 0-20 mA or 4-20 mA or 20-4 mA or 20-0 mA

4

+10 Vdc user supply

Reference supply

5 mA Output current

5

Frequency reference 2

Single ended analog input 11 bit or digital input

0 to +10 Vdc or 0 to +24 Vdc

7

Output frequency

Single ended analog output

0 to +10 Vdc

9

+24 Vdc user supply

Digital I/O supply

100 mA

10

At zero frequency

Digital I/O 1

0 to +24 Vdc

11

Enable*

Digital input 2

0 to +24 Vdc

12

Run forward

Digital input 3

0 to +24 Vdc

13

Run reverse

Digital input 4

0 to +24 Vdc

14

Analog input 1/2 select

Digital input 5

0 to +24 Vdc

31(35)**

Safe Torque Off/Drive enable

STO 2

0 to +24 Vdc

32(36)**

0V STO 2

0V STO 2

0V common for STO 2

33(32)**

0V STO 1

0V STO 1

0V common for STO 1

34(31)**

Safe Torque Off/Drive enable

STO 1

0 to +24 Vdc

41

Status relay (drive OK)

Normally open contact

2 A, 240 Vac, 0.5 A, 30 Vdc inductive load

42

51 †

0V common

Common for backup supply

52 †

+24 Vdc external supply

Backup control supply

24 Vdc, 40W

Notes * C300 uses STO, so terminal 11 is unassigned ** Frames 1 to 4 (Frames 5 to 9) - different terminals by frame size

Frames 1 to 4 - the 0V terminals on the Safe Torque Off are isolated from each other and the 0V common Frames 5 to 9 - the 0V terminals on the Safe Torque Off are not isolated from each other and the 0V common The Safe Torque Off / Drive enable terminal is a positive logic only input † Terminal 51 and 52 must be connected to an external 24 V power supply if backup is required (frame sizes 6-9 only)

19

WWW.CONTROLTECHNIQUES.COM

COMMANDER C ORDERING GUIDE

How to select a drive Electrical Considerations

Drive Mechanical Mounting • Panel mounting – as standard • Wall mounting – UL conduit kits are available • Through panel mounting – frames 5 and up

• What is the supply voltage?

• Single or three phase input power?

• What is the motor rating?

• Continuous current – FLA (Full Load Amps)

• Select the drive based on motor Amps rather than power rating

Frame size

Dimensions H xW x D mm (in)

Weight kg (lb)

1

160 x 75 x 130 (6.3 x 2.95 x 5.1)

0.75 (1.65)

W

2

205 x 75 x 150 (8.07 x 2.95 x 5.9)

1.3 (3.0)

3

226 x 90 x 160 (8.9 x 3.54 x 6.3)

1.5 (3.3)

4

277 x 115 x 175 (10.9 x 4.5 x 6.9)

3.13 (6.9)

5

391 x 143 x 200 (15.39 x 5.63 x 7.87)

7.4 (16.3)

H

6

391 x 210 x 227 (15.39 x 8.27 x 8.94)

14 (30.9)

7

557 x 270 x 280 (21.93 x 10.63 x 11.02)

28 (61.70)

8

804 x 310 x 290 (31.65 x 12.21 x 11.42)

52 (114.6)

9E

1069 x 310 x 290 (42.09 x 12.21 x 11.42)

46 (101.4)

9A

1108 x 310 x 290 (43.62 x 12.21 x 11.42)

66.5 (146.6)

D

20

WWW.CONTROLTECHNIQUES.COM

COMMANDER C PRODUCT CODES

C200 03 4 0073 A 10 1 00 AB 100

Frame Size 01 - 09

Heavy Duty Current Rating x 10

CT Reserved

Product Variant AB 100 - Standard

Drive Range C200 - The lead product for the Commander C range C300 - As C200 + Dual STO

Voltage Rating 1 = 100 V 2 = 200 V 4 = 400 V 5 = 575 V 6 = 690 V

A - Internal Line Choke E - External Line Choke Required

Default Setting 00 - CT Default 01 - US Default

Note: For the STO variants just replace the C200 digits at the start of the part number with C300.

21

WWW.CONTROLTECHNIQUES.COM

COMMANDER C MODEL NUMBER AND RATINGS

Variants with C3 built-in EMC filter

Heavy Duty

Normal Duty

Input Phases

Frame Size

Product Code

Max Continuous Current (A)

Motor Shaft Power (kW)

Motor Shaft Power (hp)

Max Continuous Current (A)

Motor Shaft Power (kW)

Motor Shaft Power (hp)

100/ 120 Vac +/-10% C200-01100017A10100AB100

1

01

1.7

0.25

0.33

C200-01100024A10100AB100

1

01

2.4

0.37

0.5

For Normal Duty applications, use Heavy Duty ratings.

C200-02100042A10100AB100

1

02

4.2

0.75

1

C200-02100056A10100AB100

1

02

5.6

1.1

1.5

200/240 Vac +/-10% C200-01200017A10100AB100

1

01

1.7

0.25

0.33

C200-01200024A10100AB100

1

01

2.4

0.37

0.5

C200-01200033A10100AB100

1

01

3.3

0.55

0.75

C200-01200042A10100AB100

1

01

4.2

0.75

1

C200-02200024A10100AB100

1 | 3

02

2.4

0.37

0.5

For Normal Duty applications, use Heavy Duty ratings.

C200-02200033A10100AB100

1 | 3

02

3.3

0.55

0.75

C200-02200042A10100AB100

1 | 3

02

4.2

0.75

1

C200-02200056A10100AB100

1 | 3

02

5.6

1.1

1.5

C200-02200075A10100AB100

1 | 3

02

7.5

1.5

2

C200-03200100A10100AB100

1 | 3

03

10

2.2

3

C200-04200133A10100AB100

1 | 3

04

13.3

3

3

C200-04200176A10100AB100

3

04

17.6

4

5

C200-05200250A10100AB100

3

05

25

5.5

7.5

30

7.5

10

C200-06200330A10100AB100

3

06

33

7.5

10

50

11

15

C200-06200440A10100AB100

3

06

44

11

15

58

15

20

C200-07200610A10100AB100

3

07

61

15

20

75

18.5

25

C200-07200750A10100AB100

3

07

75

18.5

25

94

22

30

C200-07200830A10100AB100

3

07

83

22

30

117

30

40

C200-08201160A10100AB100

3

08

116

30

40

149

37

50

C200-08201320A10100AB100

3

08

132

37

50

180

45

60

C200-09201760A10100AB100

3

09

176

45

60

216

55

75

C200-09202190A10100AB100

3

09

219

55

75

266

75

100

C200-09201760E10100AB100

3

09

176

45

60

216

55

75

C200-09202190E10100AB100

3

09

219

55

75

266

75

100

380/480 Vac +/-10% C200-02400013A10100AB100

3

02

1.3

0.37

0.5

For Normal Duty applications, use Heavy Duty ratings.

C200-02400018A10100AB100

3

02

1.8

0.55

0.75

C200-02400023A10100AB100

3

02

2.3

0.75

1

C200-02400032A10100AB100

3

02

3.2

1.1

1.5

22

WWW.CONTROLTECHNIQUES.COM

C200-02400041A10100AB100

3

02

4.1

1.5

2

C200-03400056A10100AB100

3

03

5.6

2.2

3

C200-03400073A10100AB100

3

03

7.3

3

3

For Normal Duty applications, use Heavy Duty ratings.

C200-03400094A10100AB100

3

03

9.4

4

5

C200-04400135A10100AB100

3

04

13.5

5.5

7.5

C200-04400170A10100AB100

3

04

17

7.5

10

C200-05400270A10100AB100

3

05

27

11

20

30

15

20

C200-05400300A10100AB100

3

05

30

15

20

30

15

20

C200-06400350A10100AB100

3

06

35

15

25

38

18.5

25

C200-06400420A10100AB100

3

06

42

18.5

30

48

22

30

C200-06400470A10100AB100

3

06

47

22

30

63

30

40

C200-07400660A10100AB100

3

07

66

30

50

79

37

50

C200-07400770A10100AB100

3

07

77

37

60

94

45

60

C200-07401000A10100AB100

3

07

100

45

75

112

55

75

C200-08401340A10100AB100

3

08

134

55

100

155

75

100

C200-08401570A10100AB100

3

09

157

75

125

184

90

125

C200-09402000A10100AB100

3

09

200

90

150

221

110

150

C200-09402240A10100AB100

3

09

224

110

150

266

132

200

C200-09402000E10100AB100

3

09

200

90

150

221

110

150

C200-09402240E10100AB100

3

09

224

110

150

266

132

200

500/575 Vac +/-10% C200-05500030A10100AB100

3

05

3

1.5

2

3.9

2.2

3

C200-05500040A10100AB100

3

05

4

2.2

3

6.1

4

5

C200-05500069A10100AB100

3

05

6.9

4

5

10

5.5

7.5

C200-06500100A10100AB100

3

06

10

5.5

7.5

12

7.5

10

C200-06500150A10100AB100

3

06

15

7.5

10

17

11

15

C200-06500190A10100AB100

3

06

19

11

15

22

15

20

C200-06500230A10100AB100

3

06

23

15

20

27

18.5

25

C200-06500290A10100AB100

3

06

29

18.5

25

34

22

30

C200-06500350A10100AB100

3

06

35

22

30

43

30

40

C200-07500440A10100AB100

3

07

44

30

40

53

37

50

C200-07500550A10100AB100

3

07

55

37

50

73

45

60

C200-08500630A10100AB100

3

08

63

45

60

86

55

75

C200-08500860A10100AB100

3

08

86

55

75

108

75

100

C200-09501040A10100AB100

3

09

104

75

100

125

90

125

C200-09501310A10100AB100

3

09

131

90

125

150

110

150

C200-09501040E10100AB100

3

09

104

75

100

125

90

125

C200-09501310E10100AB100

3

09

131

90

125

150

110

150

500/690 Vac +/-10% C200-07600190A10100AB100

3

07

19

15

20

23

18.5

25

C200-07600240A10100AB100

3

07

24

18.5

25

30

22

30

C200-07600290A10100AB100

3

07

29

22

30

36

30

40

C200-07600380A10100AB100

3

07

38

30

40

46

37

50

C200-07600440A10100AB100

3

07

44

37

50

52

45

60

C200-07600540A10100AB100

3

07

54

45

60

73

55

75

C200-08600630A10100AB100

3

08

63

55

75

86

75

100

C200-08600860A10100AB100

3

08

86

75

100

108

90

125

C200-09601040A10100AB100

3

09

104

90

125

125

110

150

C200-09601310A10100AB100

3

09

131

110

150

150

132

175

C200-09601040E10100AB100

3

09

104

90

125

125

110

150

C200-09601310E10100AB100

3

09

132

110

150

150

132

175

Note: The listed ordering codes are for C200, 50 Hz default setting. For C300 change the model digits (C200-xxxxxxxxxxxxxxxxxxx) from C200 to C300. For 60 Hz change the Regional Default Setting digits (xxxx-xxxxxxxxxxxx00xxxxx) from 00 to 01.

23

WWW.CONTROLTECHNIQUES.COM

ACCESSORIES ORDERING GUIDE

SI option modules (available from frame size 2 and upwards)

Optional keypad

Order code

Order code

Remote Keypad

82500000000001

SI-EtherCAT

82400000018000

Remote keypad RTC

82400000019600

SI-PROFIBUS

82400000017500

Optional accessories

Order code

SI-Ethernet

82400000017900

AI-Back-up Adaptor

82500000000004

SI-DeviceNet

82400000017700

AI-Smart Adaptor

82500000018500

SI-CANopen

82400000017600

RS485 cable

4500-0096

SI-PROFINET

82500000018200

AI-485 24 V Adaptor

82500000019700

SI-I/O

82400000017800

SI-POWERLINK

82400000021600

24

WWW.CONTROLTECHNIQUES.COM

Through hole IP65 kit* UL Type 1 conduit kit

Optional external EMC filters***

Frame Size

Frame Size

Order Code

Frame Size

Order Code

Voltage

Phases

Type

Order code

5

1

3470-0067

3470-0091

All

1

Standard

4200-1000

1

6

2

3470-0055

3470-0094

All

1

Low leakage 4200-1001

7

3

3470-0079

3470-0098

100V

1

Standard

4200-2000

8

4

3470-0083

3470-0102

1

Standard

4200-2001

9A

5

3470-0119

3470-0069

1

Low leakage 4200-2002

200V

9E

6

3470-0105

3470-0059

2

3

Standard

4200-2003

7

3470-0080

3

Low leakage 4200-2004

Finger-guard grommet

8 / 9A

3470-0088

3

Standard

4200-2005

400V

Frame Size

Order Code

9E

3470-0115

3

Low leakage 4200-2006

9A / 9E

3470-0107

1

Standard

4200-3000

Retrofit kit **

1

Low leakage 4200-3001

Line reactor

200V

Frame Size

Order Code

3

Standard

4200-3004

3

Frame Size

Order Code

3

3470-0097

3

Low leakage 4200-3005

9E (400 V)

7022-0063

4

3470-0101

3

Standard

4200-3008

400V

5

3470-0066

3

Low leakage 4200-3009

Lifting tool

6

3470-0074

1

Standard

4200-4000

Frame Size

Order Code

7

3470-0078

1

Low leakage 4200-4001

200V

9A

7778-0045

8

3470-0087

3

Standard

4200-4002

4

9E

7778-0016

9A / 9E

3470-0118

3

Low leakage 4200-4003

3

Standard

4200-4004

Fan replacement kit

400V

3

Low leakage 4200-4005

Frame Size

Order Code

200V

3

Standard

4200-0312

5

1

3470-0092

400V

3

Standard

4200-0402

2

3470-0095

200V

3

Standard

4200-2300

6

3

3470-0099

400V

3

Standard

4200-4800

4

3470-0103

7

200V & 400V 3

Standard

4200-1132

8

200V & 400V 3

Standard

4200-1972

*IP65 / UL TYPE 12 rating is achieved on the rear of the drive when through panel mounted using the following kits.

**These mounting brackets ensure the drive can be mounted on existing Commander SK installations.

9

200V & 400V 3

Standard

4200-3021

***Commander C built-in EMC filter complies with EN/IEC 61800-3. External EMC filters are required for compliance with EN/IEC 61000-6-4 as per the table below.

25

WWW.CONTROLTECHNIQUES.COM

Control Techniques has been designing andmanufacturing the best variable speed drives in the world since 1973. Our customers reward our commitment to building drives that outperform the market. They trust us to deliver on time every time with our trademark outstanding service. More than 45 years later,we’re still in pursuit of the best motor control, reliability and energy efficiency you can build into a drive. That’swhatwe promise to deliver, today and always.

1.5K+ Employees

70 Countries

26

WWW.CONTROLTECHNIQUES.COM

#1 FOR ADVANCED MOTOR AND DRIVE TECHNOLOGY

Nidec Corporation is a global manufacturer of electric motors and drives. Nidec was set up in 1973. The company made small precision AC motors and had four employees. Today, it’s a global corporation that develops, builds and installs cutting-edge drives,motors and control systems in over 70 countries with a workforce of more than 110,000. You’ll find its innovations in thousands of industrial plants, IoT products, home appliances, cars, robotics, mobile phones, haptic devices, medical apparatus and IT equipment all over the world.

112K Employees

$14.2B Group Turnover

44+ Countries

337+ Companies

27

CONTROL TECHNIQUES. NO ONE KNOWS DRIVES LIKEWE DO. Our drive obsessive representatives will drive you in the right direction and give you first class support whenever you need it.

For more information, or to find your local drive centre, visit:

www.controltechniques.com www.driveobsessed.com

Connect with us

©2022 Nidec Control Techniques Limited. The information contained in this brochure is for guidance only and does not form part of any contract. The accuracy cannot be guaranteed as Nidec Control Techniques Ltd have an ongoing process of development and reserve the right to change the specification of their products without notice.

Nidec Control Techniques Limited. Registered Office: The Gro, Newtown, Powys SY16 3BE.

Registered in England andWales. Company Reg. No. 01236886.

P.N.0778-0509-06 01/22