FIRE RISK MITIGATIONS FOR EXAMPLE BUILDING 1
Intervention
Reason for inclusion
Not required unless identified through the QDR and development of the fire strategy as a requirement. Not required unless identified through the QDR and development of the fire strategy as a requirement. To satisfy Principle 1(a) providing alternative means of vertical escape. May not be required for buildings <11m. To satisfy Principle 4(a) demonstrating fire does not spread beyond the story of origin (unless concluded through the QDR and agreed with approving authorities, insurers and other stakeholders as not being required). To satisfy Principle 4(a) demonstrating fire does not spread beyond the story of origin (unless concluded through the QDR and agreed with approving authorities, insurers and other stakeholders as not being required). Not required unless identified through the QDR and development of the fire strategy as a requirement. Not required unless identified through the QDR and development of the fire strategy as a requirement. To satisfy Principle 6, preventing simultaneous ignition on the top and bottom of the mass timber slab (unless concluded through the QDR and agreed with approving authorities, insurers and other stakeholders as not being required). To satisfy Principle 4(a) and 4(b), mitigating internal (vertical) and external fire spread (unless concluded through the QDR and agreed with approving authorities, insurers and other stakeholders as not being required). Not required unless identified through the QDR and development of the fire strategy as a requirement. To satisfy Principle 4(a), mitigating internal (vertical) fire spread (unless concluded through the QDR and agreed with approving authorities, insurers and other stakeholders as not being required).
Sprinklers
Non-combustible core
Minimum two staircases
Compartmentation between floors
Façade design to prevent floor to floor fire spread
Demonstration of auto-extinction
Heat-resistant adhesives
Protection to top of mass timber slab
Non-combustible façade construction
Fire and Rescue Service required to tackle smouldering fire
Connections between floors enclosed in fire resisting construction
KEY
Possible intervention required
Intervention required
84
Example Buildings
Made with FlippingBook - professional solution for displaying marketing and sales documents online