Schneider Manual Motor Starter

Deca ‐ Frame 2 Motor circuit breakers ‐ Thermal‐magnetic Motor circuit breakers from 0.06 to 30 kW / 415 V, Rotary handle

415V

Setting Range

kW

Part Number

Description

of thermal trips (A)

SEGV2P01 SEGV2P02 SEGV2P03 SEGV2P04 SEGV2P05 SEGV2P06 SEGV2P07 SEGV2P08 SEGV2P10 SEGV2P14 SEGV2P16 SEGV2P20 SEGV2P21 SEGV2P22 SEGV2P32

TeSys Deca, 3P, 0.1 to 0.16A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 0.16 to 0.25A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 0.25 to 0.4A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 0.4 to 0.63A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 0.63 to 1A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 1 to 1.6A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 1.6 to 2.5A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 2.5 to 4A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 4 to 6.3A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 6 to 10A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 9 to 14A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 13 to 18A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 17 to 23A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 20 to 25A, thermal magnetic, screw clamp terminals TeSys Deca, 3P, 24 to 32A, thermal magnetic, screw clamp terminals

0.1…0.16A

0.16…0.25A 0.06kW 0.25…0.40A 0.09kW 0.40…0.63A 0.18kW 0.63…1A 0.25kW 1…1.6A 0.55kW 1.6…2.5A 0.75kW

2.5…4A 4…6.3A 6…10A 9…14A 13…18A 17…23A 20…25A 24…32A

1.5kW 2.2kW

4kW

5.5kW 7.5kW

9kW

11kW 15kW

Deca ‐ Frame 2 Motor circuit breakers ‐ Add‐on blocks and accessories Contact blocks

Types of

Part Number

Description

Mounting Contacts

Auxiliary contact block,Fault signalling contact + instantaneous, TeSys Deca, 1 NO + 1 NC, for GV2P/GV2ME/GV3P Auxiliary contact block,Fault signalling contact + instantaneous, TeSys Deca, 2 NC, for GV2P/GV2ME/GV3P Short‐circuit signalling contact, for GV2P/GV2ME/GV3P Auxiliary contact block,Fault signalling contact + instantaneous, TeSys Deca, 2NO, for GV2P/GV2ME/GV3P Auxiliary contact block,TeSys Deca, 1NO/NC,front mounting, for GV2P/GV2ME/GV3P Auxiliary contact block,TeSys Deca, 1NO + 1NC,front mounting, for GV2P/GV2ME/GV3P Auxiliary contact block,TeSys Deca, 2NC,front mounting, for GV2P/GV2ME/GV3P Auxiliary contact block,TeSys Deca, 1NO+1NC,left side mounting, for GV2P/GV2ME/GV3P Auxiliary contact block,TeSys Deca, 2NO,left side mounting, for GV2P/GV2ME/GV3P

SEGVAE1

Front N/O or N/C

SEGVAE11

Front

N/O + N/C

SEGVAE20

Front N/O + N/O

SEGVAN11

Side (LH)

N/O + N/C

SEGVAN20

Side (LH)

N/O + N/O

SEGVAD1010

Side (LH)

N/O + N/O

SEGVAD1001

Side (LH)

N/O + N/C

SEGVAD0101

Side (LH)

N/C + N/C

SEGVAM11

Side (LH)

Auxiliary contact block,TeSys Deca,1NO(fault)+1NO,front mounting,for GV2/GV3P

SEGVAED101

Front N/O + N/O

Auxiliary contact block,TeSys Deca,1NO(fault)+1NC,front mounting,for GV2/GV3P

SEGVAED011

Front

N/O + N/C

_________________________________________ www.remtron.com.au Page 24 of 129 shop.remtron.com.au