Macx Intrisically Safe Isolating Barriers

Analogue Isolation Barriers Phoenix

Output Dimensions

Part Number

Input Single

MACX MCR‐EX‐SL‐RPSSI‐I Ex‐i repeater power supply and input isolation amplifier, HART. Sends fed or active 0/4‐20 mA signals (2), from the Ex area to a load (active or passive) to the safe area. Electrical 3‐way isolation, SIL 2 in accordance with IEC 61508. MACX MCR‐EX‐SL‐RPSSI‐2I Measuring transducer power supply and input isolating amplifier, HART‐ transparent. Transfers supplied or active 0/4‐20 mA signals from the Ex area galv. isolated to two loads in the safe area. Galvanic 4‐way isolation, SIL 2 according to IEC 61508, screw connection

PH2865340

Single

24VDC

Analogue

0‐20ma 4‐20ma Output

0‐20ma 4‐20ma

PH2865366

Single

Dual

24VDC

Analogue

0‐20ma 4‐20ma Output

Input

0‐20ma 4‐20ma

MACX MCR‐EX‐SL‐IDSI‐I Ex‐i output isolating amplifier, HART Isolates and sends intrinsically safe 0/4‐20 mA signals to a load (I/P converters, control valves, displays) in Ex areas. Electrical 3‐way isolation, wire break recognition, SIL 2 in accordance with IEC 61508.

PH2908060

Single

Single 0‐2ma 4‐20ma

24VDC

Analogue

Output 0‐20ma 4‐20ma

Iput

Temperature Isolation Barriers Phoenix

Output Dimensions

Part Number

Input Single Input

PH2865654

Single

24VDC

4‐20ma

MACX MCR‐EX‐T‐UI‐UP Freely programmable Ex‐i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2‐, 3‐, or 4‐wire technology, thermocouples, galvanic isolation, wide‐range power supply, screw connection, SIL 2 Ex‐i temperature measuring transducer: Converts signals from resistance thermometers installed in Ex areas and transmits a 0/4‐20 mA signal to a load in the safe area. Freely programmable, 3‐way isolation, SIL2 MACX MCR‐EX‐SL‐TC‐I‐NC Ex‐i temperature measuring transducer: Converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4‐20 mA signal to a load in a safe area. Freely programmable, 3‐way isolation, SIL2

T.Couple

and I N/O

RTD

Relay

M.Volt

Output

PH1050222

Single Input

Single 0‐2ma

24VDC

RTD

4‐20ma Output

PH1050233

Single Input

Single 0‐2ma

24VDC

T.Couple

4‐20ma Output

M.Volt

20‐80MV

All models listed are IECEx certified which is accepted in all above ground industries in Australia as well as for underground coal mines in NSW, but not in QLD _________________________________________ www.remtron.com.au Page 68 of 129 shop.remtron.com.au