6.2.10 SILENCER - Silencers are manufactured from 11 and 14 gauge carbon steel. The silencers are lined with a minimum of 3” of a sound damp ing material. When installing a rectangular silencer, install on the flange side of the motor can. When installing a round silencer, install on top of the motor can (this may require a supplied cone to install) 6.2.11 SMOKE DETECTION – Smoke detectors are available in a variety of models. Smoke detectors should be installed by qualified individuals and in accordance with any local, state, or national codes/regulations/laws (if any). 6.2.12 SPRINKLERS - Unless otherwise requested, the sprinklers discharge at 165 o F. Sprinklers must be connected to the plant’s main s prinkler system and in accordance with any local, state, or national codes/regulations/laws (if any).

6.2.13 FILTERS

Standard:

-Fire Retardant 80/20 Cellulose/Polyester Blend

Optional:

-Fire Retardant Nanofiber -Spunbond (Washable) -Other configurations are available upon request

6.2.14 TURBO DIGITAL PULSE CONTROL – This electronic device constantly monitors the differential pressure across the cartridge filters and, when the programmable set point is met, automatically reverse pulse cleans the cartridge filters. The unit also offers a cycle down feature, whereby the filters are cleaned on shutdown.

6.2.15 CUSTOM PAINT

7. INSTALLATION

7.1 Initial Considerations

7.1.1 The location of the unit(s) must be planned to maximize effective operation and simultaneously afford access for service/maintenance, while keeping safety considerations at the forefront. Explosions and fires in collection systems are not uncommon; therefore, systems should be designed and placed with those two aspects in mind and in accordance with any local, state, or national fire/safety codes/regulations. Thought should also be given to electrical and compressed air sources, keeping in mind that the collector will need to be connected with electricity, compressed air, and fire detection/suppression systems (optional). Should additional questions arise, or assistance is needed consult your Clean Air Industries distributor.

7.1.2 After the installation, access/clearance must be available to service the following

components:

1. Filters 2. Fan 3. Valves 4. Controls 5. Dust drawer