Amtech EBM Environmental Booth Module User Manual

7.2 Mechanical

NOTE: All of the mechanical installation must be performed by a qualified installer and in accordance with local, state, and national codes/regulations/laws (if any).

7.2.1 The Environmental Booth Module is a (usually) custom built booth coupled with a factory assembled dust collector. Placement/movement of the unit inside the factory/building is usually the major concern. Ensure you have enough room in front of the access doors and/or dust drawers for easy filter access as well as all around the unit for access in the event of maintenance or emergency. 7.2.2 After placement, the collector (and booth) should be secured to the floor using tapered anchor bolts. NOTE: Should questions arise concerning total weight, consult your Clean Air Industries Distributor or Clean Air Industries Factory. 7.3 Electrical

NOTE: All of the electrical installation must be performed by a qualified electrician and in accordance with local, state, and national codes/regulations/laws (if any).

7.3.1 The blower motor is typically configured to operate with 208-230/460 volt, 60 cycles, and 3 phase electrical power, unless specified otherwise with the equipment order. A magnetic motor starter with over load protection is attached to the unit. The voltage for which the starter control (and motor) is configured should be labeled on the starter control box. The electrical connections to the box (and wiring) must be sized and selected in accordance with local, state, and national codes.

7.3.2 Nominal Full Load Amperes are as follows:

Voltage

Horse Power

208V

230V

460V

575V

3

10.0

8.0

4.0

3.5

5

15.00

13.0

6.5

5.0

7.5

20.0

18.0

9.0

7.0

10

30.0

24.0

12.0

10.0

15

40.0

37.0

18.5

15.0

7.3.3 The blower is designed to rotate clock wise when viewed from the motor side (top of blower). If the blower is running in reverse, the air volume will be approximately 50% of the designed air volume and excessive noise will be generated. Therefore, once the motor is wired, check motor rotation by energizing the blower motor for a brief instant (“JOG”). If direction is reversed, then correct. Switching two (2) of the 3-phase connections on the output side will reverse the direction of rotation.

7.3.4 If your unit is equipped with the “ Turbo Digital Pulse Control ” , then this feature will need to be connected to a 120 volt power source. Power consumption is less than 50 Watts.

7.3.5 If your unit is equipped with a “light kit”, then this feature will need to be connected to a 120 volt power source.