60-Series Customization Possibilities
5 steps to customize your roof
Select roof type:  Top mount  Flush integrated Define dimensions:  Length  Width  Curvature Select panel design:  Acrylic  Glass  Sandwich Select frame finish:  Anodizing  Powder coating
1
2
3
4
Select options:  Motor cover  Fixed panel  Sunblind / flyscreen  24 V DC (12 V DC is standard)
5
Figure 2
Figure 3
Figure 1
Technical specifications Maximum cut-out size dimensions for our customized roofs
Max. lenght L1 (mm)
Max. width W1 (mm)
Corner curvature R1 (mm)
Min. cross curvature R2 (mm)
Figure 1 Roof without cross beam
1,100
1,100
80
7,500
Figure 2 Roof with cross beam in sliding direction
1,100
1,800
80
7,500
Figure 3 Roof with cross beam
1,500
1,100
80
7,500
perpendicular to sliding direction
192