Communication Protocols
The LA6-POE accepts HTTP commands sent through a web browser or PLC to trigger visual and audible alert functions.
HTTP Commands
■ Detailed Motion Control Execute command (Tier 1: Green, Tier 2: Blue, Tier 3: Off, Tier 4: White, Tier 5: Red, Flashing off, Alarm: Pattern 11) http://192.168.10.1/api/control?color=46091&buzzer=11 (The color of each tier can be controlled.) (Configure Smart Mode settings via the EDITOR software.) ■ Smart Mode Control Execute command (Run smart mode group No.10) http://192.168.10.1/api/control?smart=10
Network Camera
NVR
SOCKET Communication By using PNS commands, you can control all notification patterns. PNS Commands supported ■ Detailed Motion Control Execute command (Tier 1: Green, Tier 2: Blue, Tier 3: Off, Tier 4: White, Tier 5: Red, Flashing off, Alarm: Pattern 11) 41H, 42H, 44H, 00H, 00H, 07H, 04H, 06H, 00H, 09H, 01H, 00H, 0BH (Control specific LED colors for tiers 1 to 5) (Configure Smart Mode settings via the EDITOR software.) ■ Smart Mode Control Execute command (Run smart mode group No.10) 41H, 42H, 54H, 00H, 00H, 01H, 0AH
PNS Command
Control with 2-byte command.
Execute command (Tier 1: Continuous ON, Tier 2: Flashing, Tier 3: Off, and Alarm: Pattern 2) 57H, 51H
P
* Control the Continuous ON, Flashing, and 2 Alarms on tiers 1~3.
The LA6-POE accepts Modbus TCP/UDP commands from a PLC to control visual and audible alert functions.
Modbus/TCP
■ Smart Mode Control
(Configure Smart Mode settings via the EDITOR software.)
Execute command (When operating the Signal Tower in Smart Mode group number 15.) 00H, 00H, 00H, 00H, 00H, 06H, 01H, 06H, 00H, 06H, 01H, 0FH
PLC
21