RTT Powder Booth User Manual (2020)

9. Anchor floor channel to floor at a minimum of every 12 inches. 10. Caulk all panel joints inside the booth with the caulk provided. Do not use a silicone caulk. 11. If booth is supplied with a personnel door or front filter doors, apply foam gasket to perimeter of all door openings. Attach door hardware and adjust latches. Level door with doors off, then attach doors to hinges.

4.6 l Ights

^ WaRNING

Prevent serious injury or death. Electrical installations must be performed by qualified electricians. Installation must conform to all national, local, and provincial codes and standards.

1. Place light fixture into booth panel, center in opening, and mark locations for mounting holes. 2. Install light fixture in panel from outside of booth as shown in drawing. When mounting fixture horizontally, make sure that ballast locates to the bottom of fixture. 3. Caulk perimeter of light fixture lens frame with appropriate caulking. 4. The fixture is provided with an interlock switch that has a normally open contact, which opens when the fixture lens is removed from fixture. The switch is to be wired to disable powder application equipment used in spray booth.