Core Labs Training_Catalogue-v2 (edit 2)-web

Trace Elemental Analysis by Inductively Coupled Plasma Mass Spectrometry (ICP- MS) INORGANICS

INORGANICS

Trace Elemental Analysis by Inductively Coupled Plasma Optical Emission Spectrometry

Inductively coupled plasma optical emission spectrometry (ICP-OES) is a trace-level, elemental analysis technique that uses the emission spectra from a sample in high temperature plasma to identify and quantify the elemental com- position with detection limit at ppm level. This course introduces the fundamen- tal concepts and principles of ICP-OES analysis, including a discussion of its strengths, challenges, and typical applications. General guidance for solid sam- ple microwave digestion, sample introduction, instrument configuration, method development, software usage, and data process will be discussed. Following this course, the user is expected to be able to independently operate the instrument and perform basic data analysis. PARTICIPANT PROFILE This course is intended for students and research professionals from KAUST, and their collaborators from academia and industry. PREREQUISITES • Active Badger account

Inductively coupled plasma mass spectrometry (ICP-MS) is a highly sensitive el- emental analysis technique capable of detecting metals and several non-metals at ppb to sub-ppb concentrations. This course intends to introduce the funda- mental concepts and principles of ICP-MS analysis, including a discussion of its strengths, challenges, and typical applications. General guidance for sample in- troduction, instrument configuration, software usage, method development, and data process will be discussed. Following this course, the user is expected to be able to independently operate the instrument and perform basic data analysis.

PARTICIPANT PROFILE This course is intended for students and research professionals from KAUST, and their collaborators from academia and industry. General knowledge of the

technique is required. PREREQUISITES • Active Badger account

• Laboratory Safety Training • Hazardous Waste Training • Emergency Incident Preparedness Training • Hydrofluoric Acid Safety Training • Microwave Digestion Training (offered in ICP-OES_acl training) MAXIMUM PARTICIPANTS 2 DURATION 3 hours FREQUENCY Twice weekly

• Laboratory Safety Training • Hazardous Waste Training • Emergency Incident Preparedness Training

• Hydrofluoric Acid Safety Training MAXIMUM PARTICIPANTS 2 DURATION 3 hours FREQUENCY Weekly

Learn Develop Excel

Specialized Instrument & Method Training Catalog

Edition 1, S e pt e mber 2020

23

Made with FlippingBook - Online catalogs