12.1.6 When servicing pulse valves, refer to the diagram below
Item
Description
DP 20 (3/4") DP 25 (1") DP 40 (1 1/2")
1 2 3 4 5 6 7 8 9
Core Tube
TP10 NGP M10 BH10
TP10 NGP M10 BH10
TP10 NGP M10 BH10
Plunger Assembly
Nut & Washer
Coil
Connector
PG9
PG9
PG9
Screws & Washer
M 6 X 20
M 6 X 20
M 6 X 20
Cover
C 25 M 25
C 25 M 25
C 25 M 25
Diaphragm
Screws & Washer
M 8 X 20
10 11 12 13 14 15 16
Middle Cover
I C 40
Diaphragm Spring Main Diaphragm
S R
M 40
Body
BDD 20 GCON20
BDD 25 GCON25
BDD 40 GCON40
Conic Seal
Seal Retainer
OG20
OG25
OG40
Coupling
TDAL20
TDAL25
TDAL40
NOTE: Electrical power and compressed air supply MUST be disconnected before beginning the filter installation. NOTE FOR NON-WASHABLE (PAPER FILTER) FILTER CARTRIDGES: Do not wet or clean the cartridge filters with any liquid as it may form unwanted blockage on the filter media.