catalog

AC Series dimensions

2

10.50

2.31

L

9.88

5.25

6.31

0.62

K N J

0.75

Approximate E

A

10.36

1.62

1.75

G

Air Flow

NAMEPL

H

B

C

F

3

1.25

D

M *

1

0.56"Dia. Mounting Hole (6x)

H G DIMENSIONS (inches) F E

M SAE

M NPT

Model

A B C D

J

K

L

16 SAE 1 5/16 - 12UN-2B Thread 20 SAE 1 5/8 - 12UN-2B Thread

1.00 1.00 1.00 1.25 1.25 1.25 1.25 1.25

12.94 17.13 18.50 21.81 24.81 29.75 31.94 39.75

16.81 21.00 22.38 25.81 28.68 33.63 35.81 43.63

5.90 6.56 7.88 9.19

17.56 17.13 17.44 17.56 17.56 17.63 20.75 19.63

11.69 15.88 17.25 20.56 23.56 28.50 30.69 38.50

9.19 10.50 13.12 15.75 21.00 24.94 27.56 34.12

11.81 13.13 15.75 18.38 23.63 27.56 30.19 36.75

8.31 12.50 13.88 17.19 20.19 25.13 27.31 35.13

7.69 8.88

14.81 19.00 20.38 23.81 26.68 31.63 33.81 41.63

AC - 5 - AC - 10 - AC - 15 - AC - 20 - AC - 25 - AC - 30 - AC - 35 - AC - 40 -  Represents options.        

____

____

11.50 14.00 19.25 23.19 25.81 32.38

____

____

11.81 13.78 15.09 18.38

____

11.00 11.00 13.25

Notes: 1) Removable base mounting brackets are supplied with unit at no additional charge. 2) 1/2-12 UNC-2B Tabs, 4 points, 8 points on models AC - 30,35 & 40 (top & bottom) for optional mounting purposes. 3) Motor mounting bracket is rotated 90 degrees on AC - 5 & 10 units.

4) Louvers are manually adjustable. However, all units are available with a screen front as an option (specify when ordering). 5) All units are available with an optional preset 30 or 65-psi pressure bypass valve. (see note "i" in maintenance on page 143) 6) All units can be connected in one or Two Pass configuration. Refer to piping instructions for detailed operating andmaintenance information.

Example of a model:

AC - 35 - 3 - S - R65 - 2P -____ - ____

Model

Coating Blank = Enamel (standard) G = Galvanize (cabinet) T = Heresite (core) X = Epoxy (cabinet) STS = Stainless Steel (cabinet)

Size

Tubing Blank = Copper C = Carbon Steel U = 90/10 CN SS = Stainless Steel

Drive Type

Connections

N = no motor 1 = single phase 3 = three phase

Number of Passes 1P = 1 pass 2P = 2 pass

Blank = NPT S = SAE O-Ring F = 4 Bolt Flange A = ANSI 150#RF Flange

Bypass R30 = 30psi R65 = 65psi

1EXP = single phase 3EXP = three phase 5 = 575 Volt

note: AIHTI reserves the right to make reasonable design changes without notice.

160

Copyright © 2019 - 2020 American Industrial Heat Transfer, Inc.

355 American Industrial Drive LaCrosse, VA 23950

tel: 434-757-1800

fax: 434-757-1810

email: sales@aihti.com

Made with FlippingBook - professional solution for displaying marketing and sales documents online