catalog

AOCS Series performance

ONE PASS

70000 60000

J K

G H I

F

C D E C D E

B

J K

G H I

F

B

40000

I

G H J K

F

C D E C D E

AOCS-2010 AOCS-2515 AOCS-3120 AOCS-3525 AOCS-4030

B B

J K

G H I

F

J K

G H I

F

20000

C D E

B

J

F G H I

10000

AOCS-1505

E

B C D

6000 8000

G H I

A

Fs

F

AOCS-1005

D E

B C

G

A

F

E

AOCS-453 AOCS-603

B C D

4000

A

F

E

D

B C

A

F

D E

AOCS-303

B C

2000

A

E

C D

AOCS-201

B

A

1000

700

20

30 40 50 60 70 80

200

300 400 500 600 800

10

100

1000

GPM

TWO PASS

200000

AOCS-3525 AOCS-4030

100000 60000 80000

E

F

G H

I

J

K

E

F

G H

I

J

K

E

F F

G H

I

J

K

AOCS-2010 AOCS-2515 AOCS-3120

40000

E

G H

I

J

K

K

J

F

G H

I

E

20000

Fs

K

J

I

G H

F

E

AOCS-1005 AOCS-1505

10000 6000 8000

J K

I

G H

F

E

J

I

K

H

G

F

E

AOCS-453 AOCS-603

J

K

I

H

G

4000

F

E

I

J

H

G

F F

E

AOCS-303

H

G

2000

E

AOCS-201

1000

10

20

30

40

50 60

70 80 90

100

200

300

400

500

GPM

PERFORMANCE CALCULATION

OIL PRESSURE DROP (PSI) CODE

B = 2 PSI C = 3 PSI D = 4 PSI

H = 20 PSI I = 25 PSI J = 30 PSI

K = 35 PSI

E = 5 PSI F = 10 PSI G = 15 PSI

F s =

Horsepower to be removed (HP) x 2545 x Cv ° F (Oil Leaving* - Ambient Air Entering)

BTU hr °F =

* Represents desired fluid leaving the cooler.

Note: When a model selection has been made, record whether the selection was from the one pass curve or the Two Pass curve so that the unit can be properly plumbed. Incorrect installation can seriously affect the performance.

note: AIHTI reserves the right to make reasonable design changes without notice.

191

Copyright © 2019 - 2020 American Industrial Heat Transfer, Inc.

tel: 434-757-1800 355 American Industrial Drive LaCrosse, VA 23950

email: sales@aihti.com fax: 434-757-1810

Made with FlippingBook - professional solution for displaying marketing and sales documents online