AOCS Series motor data
ELECTRIC MOTOR DATA
Horse Power
NEMA Frame
2.9/1.5 1.13 7.6/3.8 3.05 8.3/4.2 3.34 13.5/6.7 5.39 27.6/13.8 11.0 35.8/17.9 14.3 48.4/24.2 19.4 60.8/30.4 24.3 71.6/35.8 28.6 Full Load Amperes
Service Factor
Thermal Overload
Model
Phase
Hz
Volts
RPM
Type
NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO
1.15 1.25 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25
TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC
1800 1800 1800 1800 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
1 1 3 3 3 3 5 5
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
143T 143T 182T 182T 213T 213T 215T 215T 256T 256T 284T 284T 286T 286T 324T 324T 326T 326T
AOCS-201-3 AOCS-201-5 AOCS-303-3 AOCS-303-5
208-230/460 575 208-230/460 575 208-230/460 575 208-230/460 575 208-230/460 575 208-230/460 575 208-230/460 575 208-230/460 575 208-230/460 575
AOCS-453,603-3 AOCS-453,603-5 AOCS-1005,1505-3 AOCS-1005,1505-5
10 10 15 15 20 20 25 25 30 30
AOCS-2010-3 AOCS-2010-5 AOCS-2515-3 AOCS-2515-5 AOCS-3120-3 AOCS-3120-5 AOCS-3525-3 AOCS-3525-5 AOCS-4030-3 AOCS-4030-5
NOTE: All of the AOCS Series are available in 50hz upon request as a special
ELECTRIC MOTOR NOTES:
1) All motors are NEMA, high efficiency 2) All standard direct drivemodels are suppliedwith TEFCelectric motor for continuous duty at 104 o F (40 o C). 3) The above motor electrical ratings are an approximate guide and may vary slightly between motor manufactures. Consult motor ratings listed directly on motor data plate prior to installation and operation 4) High altitude, high temperature, severe duty, crusher duty, chemical, IEC, Canadian Standards Association, and Underwriters Laboratory recognized motors are available upon request.
5) American industrial Heat Transfer, Inc. reserves the right to enact changes to motor brand, type, and ratings regarding horsepower, RPM, FLA, and Service factor for standard products without notice. All specified customer requirements will be honored without change or as directed. 6) Fan rotation is clockwise facing the motor shaft. 7) For lubrication information refer to manufactures maintenance instructions. 8) Abbreviation Index TEFC................ Totally Enclosed, Fan Cooled X-PROOF......... Explosion Proof
CLASS I,DIV.1, GROUP D or CLASS II,DIV.2, GROUP F & G EXPLOSION PROOF MOTOR DATA
Horse Power
NEMA Frame
2.8/1.4 7.8/3.9 8.8/4.4 13.6/6.8 26.6/13.3 35.0/17.5 48.4/24.2 60.8/30.4 73.4/36.7 Full Load Amperes
Service Factor
Thermal Overload
Enclosure Type
Model
Phase
Hz
Volts
RPM
YES YES YES YES YES YES YES YES YES
1800 1800 1200 1200 1200 1200 1200 1200 1200
60 60 60 60 60 60 60 60 60
3 3 3 3 3 3 3 3 3
1 3 3 5
143T 182T 213T 215T 256T 284T 286T 324T 326T
AOCS-201-3EXP AOCS-303-3EXP AOCS-453,603-3EXP AOCS-1005,1505-3EXP
208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460
1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15
EPFC EPFC EPFC EPFC EPFC EPFC EPFC EPFC EPFC
10 15 20 25 30
AOCS-2010-3EXP AOCS-2515-3EXP AOCS-3120-3EXP AOCS-3525-3EXP AOCS-4030-3EXP
NOTE: All of the AOCS Series explosion proof motors are available in 50hz upon request as a special
note: AIHTI reserves the right to make reasonable design changes without notice.
193
Copyright © 2019 - 2020 American Industrial Heat Transfer, Inc.
tel: 434-757-1800 355 American Industrial Drive LaCrosse, VA 23950