catalog

AOCS Series motor data

HYDRAULIC MOTOR DATA

Required Flow

1725 1725 1160 1160 1160 1160 1160 1160 1160 1160 1160 Motor RPM

Displacement in 3 /Rev

Case Drain

SAE Size

#12; 1-1/16-12 #12; 1-1/16-12 #12; 1-1/16-12 #12; 1-1/16-12 #12; 1-1/16-12 #12; 1-1/16-12 #16; 1-5/16-12 #16; 1-5/16-12 #16; 1-5/16-12 #16; 1-5/16-12 #16; 1-5/16-12 Side Port SAE O-Ring

Max. Continuous Pressure PSIG

400 / 290 1400 / 860 1300 / 870 1300 / 870 1500 / 1000 1500 / 1000 1750 / 1250 2000 / 1350 2500 / 1800 2500 / 1900 3000 / 2200 Oper. pressure start / run PSIG

Model

GPM

LPM

3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000

A A A A A A B B B B B

0.68 0.68 1.00 1.00 1.45 1.45 2.32 3.30 3.30 3.80 5.30

22.7 22.7 22.3 22.3 32.2 32.2 51.9 73.8 73.8 85.0 100.7

Ext. Ext. Ext. Ext. Ext. Ext. Ext. Ext. Ext. Ext. Ext.

AOCS-201- 9 AOCS-303- 9 AOCS-453- 9 AOCS-603- 9 AOCS-1005- 9 AOCS-1505- 9 AOCS-2010- 9 AOCS-2515- 9 AOCS-3120- 9 AOCS-3525- 9 AOCS-4030- 9

6.0 6.0 5.9 5.9 8.5 8.5

13.7 19.5 19.5 22.5 26.6

Note: Maximum degree of fluid contamination; Class 18/15 according to ISO 4406. Therefore, we recommend a filter with a retention rate of B 20 >. For longer life, we recommend class 17/14, achievable with a filter B10 > -100.

HYDRAULIC MOTOR NOTES:

1) Standard units are supplied with a bi-directional hydraulic gear motor for the fan drive. The gear motor requires an external case drain be used during operation. The external case drain should be connected directly to hydraulic reservoir or a return line with not greater than 10PSIG back pressure. (NOTE: Failure to properly connect and use the external case drain during motor operation could result in motor failure and external leakage of hydraulic fluid. 2) Hydraulic motor flow requirements are provided with an efficiency rating of approximately 85%. Pressure requirements are calculated theoretical minimum operating requirements. 3) Hydraulic motor load adapters are provided to bridge and align the space between the hydraulic motor and the fan. Load adapters require periodic maintenance lubrication (see accompanying information).

4) Maximum degree of fluid contamination, class 18/15 according to ISO 4406. Therefore, it is recommended to use a filter with retention rating of B20>. For longer life, it is recommended to use class 17/14 achievable with filter B10>-100. 5) A shaft coupling bushing is used on some models to join the fan drive shaft to the fan. All fans, either hub style or bushing connection, should be checked and retightened after the first 100 hours of operation. 8) American industrial reserves the right to enact changes to hydraulic motor, brand, type, ratings, port sizes, or any additional non-specified attribute for standard products without notice. All specifc requirements will be honored without change pending availability. 6) Fan rotation is clockwise when facing the motor shaft. 7) Optional displacement motors available upon request.

Example of a model:

AOCS - 1505 - 3 - S - R65 - 2P -____ - ____

Model

Coating G = Galvanize (cabinet)

Size

Number of Passes Tubing Blank = Copper U = 90/10 Cu Ni C = Carbon Steel SS = Stainless Steel 1P = 1 pass 2P = 2 pass

Drive Type

T = Heresite (core) X = Epoxy (cabinet) Blank = Enamel (standard) STS = Stainless Steel (cabinet)

N = no motor 3 = 3/60/230-460 3EXP = Explosion Proof 3/60/230-460 5 = 3/60/575 9 = Hydraulic Mtr.

Connections blank = NPT S = SAE 4 Bolt Flange A = ANSI 150#RF Flange

Bypass R30 = 30psi R65 = 65psi

COMMON DATA

Air Flow

Liquid Volume gal. cm 3

Weight Electric lb kg

Weight Hydraulic lb kg

Serviceable Core™

Sound Level dB(A) @ 13ft

Model

CFM

m 3 /s

3000 4380 5920 8750

1.7 3.8 4.8 6.1 7.7

200 310 490 580 690 910

185 260 410 490 575

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

1.41 2.07 2.79 4.13 5.97 7.65

6435 14383 18168 23089 29145 39364 86298

AOCS-201 - AOCS-303 - AOCS-453 - AOCS-603 - AOCS-1005- AOCS-1505- AOCS-2010- AOCS-2515- AOCS-3120- AOCS-3525- AOCS-4030-

77 82 78 80 84 87 92 95 99 99 99

91 141 222 263 313 413 580 730 821 898 975

84 118 186 222 261 465 482 598 673 736 799

          

12650 16150 23350 32000 39000 46000 54000

10.4 22.8 27.5 31.9 47.0 47.0

1025 1062 1320 1483 1622 1762

1280 1610 1810 1980 2150

11.73 15.00 18.40 21.71 25.48

104088 120742 177895 185466

NOTES: a)  Represents the options for motor drive. b) To estimate the sound level at distances other than 13 feet (4 meters) from the cooler, add 6 db for each halving of distance, or substract 6 db for each doubling of the distance.

note: AIHTI reserves the right to make reasonable design changes without notice.

195

Copyright © 2019 - 2020 American Industrial Heat Transfer, Inc.

tel: 434-757-1800 355 American Industrial Drive LaCrosse, VA 23950

email: sales@aihti.com fax: 434-757-1810

Made with FlippingBook - professional solution for displaying marketing and sales documents online