EOC Series performance
EOC - 1PASS SERIES
10000
2000 3000 4000 5000 6000 8000
G H
F
D E
B C
A
EOC-700
G H I J
F
C D E
B
A
G H
F
EOC-545
D E
C
B
J
A
G H I
F
EOC-575
D E
C
B
F G H J
E
D
Fs
EOC-505
B C
1000
F G
D E
A
EOC-337
B C
300 400 500 600 800
A
EOC-375
F
D E
EOC-249
C
B
A
F
D E
B C
A
EOC-190
C D E
200
B
A
EOC-220
100
1
2 3 4 5 6 7 8 9
10
20 30 40 50 60 80
100
200
300
GPM
EOC - 2PASS SERIES
10000
2000 3000 4000 6000 8000
F
G H
I
J K
D E
C
B
A
EOC-700
Example Line
J
G H
F
I
B C D E
EOC-575
J
G H I
F
B C D E
EOC-545
J
F G H I
D E
C
B
EOC-505
EOC-375
F G H J
D E
C
B
A
I
J
Fs
1000
G H
F
EOC-337
C D E
B
300 400 500 600 800
A
I
G H
F
EOC-249
D E
C
B
A
G H I
F
EOC-220
D E
B C
A
EOC-190
F
200
C D E
B
A
100
1
2
3 4 5 6 7 8 9
10
20 30 40 50 60 80
100
GPM
PERFORMANCE CALCULATION
OIL PRESSURE DROP (PSI) CODE
A = 1 PSI B = 2 PSI C = 3 PSI
J = 30 PSI K = 35 PSI
G = 15 PSI H = 20 PSI I = 25 PSI
D = 4 PSI E = 5 PSI F = 10 PSI
F s =
Horsepower to be removed (HP) x 2545 x Cv °F (Oil Leaving - Ambient Air Entering)
BTU hr ° F
=
Represents desired fluid leaving the cooler.
Note: When a model selection has been made, record whether the selection was from the one pass curve or the Two Pass curve so that the unit can be properly plumbed. Incorrect installation can seriously affect the performance.
note: AIHTI reserves the right to make reasonable design changes without notice.
214
Copyright © 2019 - 2020 American Industrial Heat Transfer, Inc.
355 American Industrial Drive LaCrosse, VA 23950
tel: 434-757-1800
fax: 434-757-1810
email: sales@aihti.com
Made with FlippingBook - professional solution for displaying marketing and sales documents online