EOC & EOCF S eries motor data

HYDRAULIC MOTOR DATA

Min.Operation Pressure (PSI)

Maximum Pressure (PSI)

Min.Oil Flow Required (GPM)

Motor Con- nections

Displacement IN 3 /Rev

No. of Motors

Size

Shaft

RPM

Model

EOC-190 EOC-220 EOC-249 EOC-337 EOC-375 EOC-505 EOC-545 EOC-575 EOC-700

1

SAE A 2 Bolt

.625 Keyed Short

3000

SAE-12 1 - 1/16 -12

1725

200

.43

3.75

2

400

.68

6.00

HYDRAULIC MOTOR NOTES:

between the fan and hydraulic motor. 4) Maximumdegree of fluid contamination, class 18/15 according to ISO 4406. Therefore, it is recommended to use a filter with retention rating of B20>. For longer life, it iscommended to use class 17/14 achievable with filter B10>-100. 5) Fan rotation is clockwise when facing the motor shaft. 6) Optional displacement motors available upon request. 7) American industrial reserves the right to enact changes to hydraulic motor, brand, type, ratings, port sizes, or any ad- ditional non-specified attribute for standard products without notice. All specifc requirementswill be honoredwithout change pending availability.

1) Standard units are supplied with a bi-directional hydraulic gear motor for the fan drive. The gear motor requires an external case drain be used during operation. The external case drain should be connected directly to hydraulic reservoir or a return line with not greater than 10PSIG back pressure. (NOTE: Failure to properly connect and use the external case drain duringmotor operation could result inmotor failure and external leakage of hydraulic fluid. 2) Hydraulic motor flow requirements are provided with an ef- ficiency rating of approximately 85%. Pressure requirements are calculated theoretical minimum operating requirements. 3) Shaft adapters are used to bridge the differences in length

Total Air Flow

Liquid Volume gal.

Weight Electric lb kg

Weight Hydraulic lb kg

Sound Level dB(A) @ 7ft

Bypass Valve Adder (lbs)

Serviceable Core

Model

CFM

.376 .376 .942 m 3 /s

cm 3

5 5 5 6 6 7 7 8 8

20 27 37 44 59 63 68

44 59 82 97

22 29 39 46 64 68 74

800 800

.76 .85

49 64 87

NO NO NO NO NO NO NO NO YES

EOC-190 EOC-220 EOC-249 EOC-337 EOC-375 EOC-505 EOC-545 EOC-575 EOC-700

2877 3217 4845 7003 7343 9464

68 68 71 81 73 73 73 83 87

2000 2500 4000 4000 4000 5000 9500

1.28 1.85 1.94 2.50 3.51 4.34 7.53

102 142 151 163 241 428

1.177 1.884 1.884 1.884 2.355 4.475

130 139 151 227 414

13287 16428 28504

103 188

109 194

NOTES: To estimate the sound level at distances other than 7 feet (2.1 meters) from the cooler, add 6 db for each halving of distance, or substract 6 db for each doubling of the distance.

Electrical Temperature controller with Bulb Well Assembly (for Air / Liquid Coolers)

Part Number

Description

310-4011 310-4002 310-2025

TC-511 with 6-Foot Capallary Tube & Bulb Well TC-511 with 20-Foot Capallary Tube & Bulb Well

Replacement Bulb Well TC-511

note: AIHTI reserves the right to make reasonable design changes without notice.

222

Copyright © 2019 - 2020 American Industrial Heat Transfer, Inc.

355 American Industrial Drive LaCrosse, VA 23950

tel: 434-757-1800

fax: 434-757-1810

email: sales@aihti.com

Made with FlippingBook - professional solution for displaying marketing and sales documents online