ACA Series motor data
ELECTRIC MOTOR DATA
Enclosure Type
Horse Power
NEMA Frame
Full Load Amperes
Service Factor
Thermal Overload
Model
Phase
Hz
Volts
RPM
.25 .25 .33 .25 .25 .50 .50 .50 .50 .50 .50 .50 1.0 1.0 1.0 1.0 1.0 1.0 3.0 3.0 5.0 5.0 5.0 5.0 7.5 7.5
1 3 3 1 3 3 1 3 3 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
ACA-3181/2 ACA-3181/2 ACA-3181/2 ACA-3241/2 ACA-3241/2 ACA-3241/2 ACA-3301/2 ACA-3301/2 ACA-3301/2 ACA-4301/2 ACA-4301/2 ACA-4301/2 ACA-6301/2 ACA-6301/2 ACA-3361/2 ACA-3361/2 ACA-4361/2 ACA-4361/2 ACA-6361/2 ACA-6361/2 ACA-6421/2 ACA-6421/2 ACA-6481/2 ACA-6481/2 ACA-6541/2 ACA-6541/2 ACA-6601/2 ACA-6601/2
TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC
2.6/1.3 1.4/.07 0.6 5.2/2.6 1.4/0.7 2.0/1.0 7.8/3.9 2.4/1.2 1.0
115/230 230/460 575 115/230 230/460 575 115/230 230/460 575 115/230 230/460 575 230/460 575 230/460 575 230/460 575 230/460 575 230/460 575 230/460 575 230/460 575 230/460 575
1800 1800 1800 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1800 1800 1200 1200 1200 1200 1200 1200 1200 1200
48 48 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56
1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15
NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO
7.8/3.9 2.4/1.2 1.0 3.6/1.8 1.5 3.6/1.8 1.5 3.6/1.8 1.5 8.4/4.2 3.05 13.66/6.83 5.39 13.66/6.83 5.39 19.96/9.98 7.99 27.6/13.8 10.6
182T 182T 213T 213T 213T 213T 254T 254T 256T 256T
10.0 10.0 NOTE: All of the ACA Series are available in 50hz upon request as a special
ELECTRIC MOTOR NOTES:
1) All motors are NEMA, high efficiency 2) Motor electrical ratings are an approximate guide and may vary between motor manufacturers. Consult ratings on motor data plate prior to installation and operation. 3) Explosion proof, high temperature, severe duty, chemical, IEC, Canadian Standards Association, and Underwriters Laboratory recognized motors are available upon request. 4) American Industrial reserves the right to enact changes to motor brand, type and ratings regarding horsepower, RPM,FLA,and service factor for standard products without notice. All specifc requirements will be honored without change.
5) Fan rotation is clockwise when facing the motor shaft.
6) The above motors contain factory lubricated shielded ball bearings (no additional lubrication is required).
7) Abbreviation Index TEFC...........................Totally Enclosed, Fan Cooled EXP.............................Explosion Proof
NOTE: Basic electric drive units are supplied with one of the corresponding above listed motors.
note: AIHTI reserves the right to make reasonable design changes without notice.
236
Copyright © 2019 - 2020 American Industrial Heat Transfer, Inc.
355 American Industrial Drive LaCrosse, VA 23950
tel: 434-757-1800
fax: 434-757-1810
email: sales@aihti.com
Made with FlippingBook - professional solution for displaying marketing and sales documents online