AOMF S eries motor data
AOMF SERIES
2000
J
1000 800
F G H I
AOMF-4
C D E
B
A
600 500 400
I J K L
F G H
AOMF-2
Fs
C D E
B
A
300
H
F G
E
AOMF-1
C D
B
A
200
100
1
2
20
30 40 50 60 80 100
200
3 4 5 6 7 8 9 10
GPM
PERFORMANCE CALCULATION
OIL PRESSURE DROP (PSI) CODE
A = 1 PSI B = 2 PSI C = 3 PSI
J = 30 PSI K = 35 PSI L = 40 PSI
G = 15 PSI H = 20 PSI I = 25 PSI
D = 4 PSI E = 5 PSI F = 10 PSI
F s =
Horsepower to be removed (HP) x 2545 x Cv °F (Oil Leaving - Ambient Air Entering)
BTU hr °F =
Represents desired fluid leaving the cooler.
AOMF ELECTRIC MOTOR DATA
Per Motor Full Load Amperes
Air Flow 950 1900 3900
No. of Motors
Volts
RPM
Model
AOMF - 1 AOMF - 2 AOMF - 4
1 2 4
12V / 24V 12V / 24V 12V / 24V
2700 2700 2700
9 / 4.5 9 / 4.5 9 / 4.5
IN or OUT
STANDARD CONSTRUCTION MATERIALS
IN or OUT
Standard Construction Materials
Standard Unit Ratings
Mount. bracket
Steel Steel
Tubes
Copper
Operating Pressure
300 psig
Cabinet
Fins
Aluminum
300 o F
Operating Temp.
Fan Blade
Aluminum
Turbulators
Steel Steel
Manifold
PIPING HOOK UP
EXAMPLE OF A MODEL
IN or OUT
IN or OUT
OUT
AOMF - 1 - S - 4
Model
Motor Size 4 = 12V Mtr. 6 = 24V Mtr.
Number of motors
Connections Blank = NPT S = SAE
1 = 1 Motor 2 = 2 Motors 4 = 4 Motors
IN
OUT
note: AIHTI reserves the right to make reasonable design changes without notice.
247
Copyright © 2019 - 2020 American Industrial Heat Transfer, Inc.
tel: 434-757-1800 355 American Industrial Drive LaCrosse, VA 23950
email: sales@aihti.com fax: 434-757-1810
Made with FlippingBook - professional solution for displaying marketing and sales documents online