catalog

AOMF S eries motor data

AOMF SERIES

2000

J

1000 800

F G H I

AOMF-4

C D E

B

A

600 500 400

I J K L

F G H

AOMF-2

Fs

C D E

B

A

300

H

F G

E

AOMF-1

C D

B

A

200

100

1

2

20

30 40 50 60 80 100

200

3 4 5 6 7 8 9 10

GPM

PERFORMANCE CALCULATION

OIL PRESSURE DROP (PSI) CODE

A = 1 PSI B = 2 PSI C = 3 PSI

J = 30 PSI K = 35 PSI L = 40 PSI

G = 15 PSI H = 20 PSI I = 25 PSI

D = 4 PSI E = 5 PSI F = 10 PSI

F s =

Horsepower to be removed (HP) x 2545 x Cv °F (Oil Leaving  - Ambient Air Entering)

BTU hr °F =

 Represents desired fluid leaving the cooler.

AOMF ELECTRIC MOTOR DATA

Per Motor Full Load Amperes

Air Flow 950 1900 3900

No. of Motors

Volts

RPM

Model

AOMF - 1 AOMF - 2 AOMF - 4

1 2 4

12V / 24V 12V / 24V 12V / 24V

2700 2700 2700

9 / 4.5 9 / 4.5 9 / 4.5

IN or OUT

STANDARD CONSTRUCTION MATERIALS

IN or OUT

Standard Construction Materials

Standard Unit Ratings

Mount. bracket

Steel Steel

Tubes

Copper

Operating Pressure

300 psig

Cabinet

Fins

Aluminum

300 o F

Operating Temp.

Fan Blade

Aluminum

Turbulators

Steel Steel

Manifold

PIPING HOOK UP

EXAMPLE OF A MODEL

IN or OUT

IN or OUT

OUT

AOMF - 1 - S - 4

Model

Motor Size 4 = 12V Mtr. 6 = 24V Mtr.

Number of motors

Connections Blank = NPT S = SAE

1 = 1 Motor 2 = 2 Motors 4 = 4 Motors

IN

OUT

note: AIHTI reserves the right to make reasonable design changes without notice.

247

Copyright © 2019 - 2020 American Industrial Heat Transfer, Inc.

tel: 434-757-1800 355 American Industrial Drive LaCrosse, VA 23950

email: sales@aihti.com fax: 434-757-1810