catalog

LP & LPR Series motor data

1000 800 600 500 400 300

F G H

C D E

600

B

A

F G

C D E

300

B

A

Fs

F G H I J

150

C D E

B

A

200

100

80 60

20

30 40 50 60 80 100

200 300

1

2

3 4 5 6 7 8 9 10

GPM

PERFORMANCE CALCULATION

OIL PRESSURE DROP (PSI) CODE

A = 1 PSI B = 2 PSI C = 3 PSI

J = 30 PSI

G = 15 PSI H = 20 PSI I = 25 PSI

D = 4 PSI E = 5 PSI F = 10 PSI

Horsepower to be removed (HP) x 2545 x Cv °F (Oil Leaving  - Ambient Air Entering)

F s =

BTU hr °F =

 Represents desired fluid leaving the cooler.

LP MOTOR DATA

Model

Volts

2700 2700 3000 2300 3000 3000 RPM

Total CFM

FLA Per Motor

9.0 / 4.5 9.0 / 4.5 13.7 / 6.6 13.7 / 6.6 13.7 / 6.6 13.7 / 6.6

950 950 950 950

LP - 150 LPR - 150 LP - 300 LPR - 300 LP - 600 LPR - 600

12 / 24 12 / 24 12 / 24 12 / 24 12 / 24 12 / 24

1900 1900

STANDARD CONSTRUCTION MATERIALS

Standard Construction Materials

Standard Unit Ratings

Mount. bracket

Steel Steel

Tubes

Copper

Operating Pressure

300 psig

Cabinet

Fins

Aluminum

300 o F

Operating Temp.

Fan Blade

Aluminum

Turbulators

Steel Steel

Manifold

PIPING HOOK-UP

IN or OUT

IN or OUT

OUT

IN

note: AIHTI reserves the right to make reasonable design changes without notice.