GES Biotek - Crater-Max® microbiological odor-control solution for Bio-Scrubbers® and Biofilters - safety data sheet
Crater-Max ® Safety Data Sheet
Section 1 - Identification
Product Identification:
Crater-Max™ Media
Product Use:
Use in accordance with manufacturer recommendations
Manufacturer:
GES Biotek, LLC, 1540 Louis Bork Dr., Batavia, IL, 60510
Telephone:
630-473-3874
Emergencies:
630-473-3874
Section 2 - Hazard(s) Identification
Hazard Classification:
Product does not meed the criteria for classification
Signal Word:
NA
Hazard Statement:
Product does not meed the criteria for classification
Hazard Pictogram:
NA
Precautionary Statements: P262:
Do not get in eyes, on skin, or on clothing IF SWALLOWED: Get medical advice/attention.
P301/P313
P305/P351/P338/P337
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. If eye irritation persists: seek medical attention
Section 3 - Composition/Information on Ingredients
Chemical Name
(CAS#)
%, wt.
Impurities
Volcanic Scoria
NA
100
NA
Section 4 - First Aid Measures
Route(s) of Exposure Symptoms
First Aid
Eye
Contact with dust May be harmful if swallowed.
Flush thoroughly with water. Seek medical attention if irritation persists. Seek medical assistance. Material is rigid and may become logged if ingested.
Ingestion
1540 Louis Bork Dr. • Batavia, IL 60510 • 630-473-3874 • gesbiotek.com
Crater-Max ® Safety Data Sheet
Section 5 - Fire-Fighting Measures
Suitable Extinguishing Media:
Use media suitable for surrounding the fire.
Unsuitable Media:
None
Unusual fire & explosion hazards:
None
Special Firefighting procedures:
Exercise caution when responding to any chemical fire. Firefighters should wear full protective gear.
Section 6 - Accidental Release Measures
Personal Precautions:
Wear protective equipment
General precautions:
Avoid contact with eyes.
Section 7 - Handling and Storage
Safe Handling:
Avoid contact with eyes.
Safe Storage:
Store in a cool, dry and well ventilated area. Protect containers from physical damage.
Section 8 - Exposure Controls/Personal Protection
Engineering Guidelines:
Local exhaust and general ventilation to meet exposure standards.
Personal Protective Equipment:
Gloves, safety glasses, work clothes as determined appropriate
General Hygiene:
Wash hands after handling
1540 Louis Bork Dr. • Batavia, IL 60510 • 630-473-3874 • gesbiotek.com
Crater-Max ® Safety Data Sheet
Section 9 - Physical and Chemical Properties
Physical State:
LEL:
Solid
NA
Boiling point:
pH:
NA
6–12
Appearance:
Vapor Density:
Solid
NA
Flash Point:
Relative Density:
Non Flammable
49–51 lbs./ft 3
Color:
Patrition Coefficient:
Red/Brown
NA
Evaporation Rate:
Melting Point:
NA
NA
Odor:
Auto ignition Temperature:
None
No Data Avail.
Flammability (solid/gas) C:
Freezing Point:
Non Flammable
NA
Odor Threshold:
Decomposition Temperature:
None
NA
UEL:
Solubility:
NA
Insoluble
Vapor Pressure:
Viscosity:
NA
NA
Section 10 - Stability and Reactivity
Incompatibility:
None
Chemical Stability:
Yes
Conditions to Avoid:
None
Materials to Avoid:
None
1540 Louis Bork Dr. • Batavia, IL 60510 • 630-473-3874 • gesbiotek.com
Crater-Max ® Safety Data Sheet
Section 11 - Toxicological Information
ACUTE EFFECTS: Ingestion:
See Section IV
Eye Irritation:
See Section IV
Skin Irritation:
See Section IV
Sensitization:
Not Determined
Signs and Symptoms of Exposure:
Irritation and redness of eyes.
CHRONIC EFFECTS: Carcinogenicity:
Not Determined
Mutagenicity:
Not Determined
Reproduction Effects:
Not Determined
Developmental Factors:
Not Determined
Section 12 - Ecological Information
Ecotoxicity:
Not Determined
Persistence/Degradability:
Not Determined
Bioaccumulation Potential:
Not Determined
Mobility in Soil:
Not Determined
Other Adverse Effects:
Not Determined
Section 13 - Disposal Considerations
Vacuum or shovel material in a closed container. Dispose of in accordance with all applicable local, state, federal and international regulations.
1540 Louis Bork Dr. • Batavia, IL 60510 • 630-473-3874 • gesbiotek.com
Crater-Max ® Safety Data Sheet
Section 14 - Transport Information
UN Number:
Not applicable
UN Name: Not applicable Ship in accordance with DOT/ADR/RID/ADNR/IMDP/ICAO/IATA
Section 15 - Regulatory Information
SARA Title III 302:
Product not listed
SARA Title III 313:
Product not listed
TSCA:
Product not listed
Canadian – WHMIS:
Product not listed
DSL#:
Product not listed
MA RTK* – substance list:
Product not listed
PA RTK* hazardous substance list:
Product not listed
*RTK – Right to Know
Section 16 - Other Information The information and recommendations listed are believed to be true and accurate to the best of our knowledge as of the prepared date below. GES Biotek LLC makes no warranty with respect to same and disclaims all liability for reliance therein.
1540 Louis Bork Dr. • Batavia, IL 60510 • 630-473-3874 • gesbiotek.com
rev 2.0 4-22-2025