Process 13 – Exhaust Fan Kit Installation
Step 1 - Installing the Exhaust Fan a) The exhaust fan and intake ductwork have been assembled in the factory along with the required airflow switches and tubing . b) The Fan will be located at the opening in the oven roof – Reference Drawing Packet for details . c) Ensure that the collar ring is installed to sit directly on top of the roof panel to deflect any heat transfer from the opening – Reference Figure 27 . d) The fan can be rotated around the opening to help in the elimination of off-sets required in the exhaust ductwork if required . Step 2 - Installing the Exhaust Ductwork – (If provided by CEFS) a) Assemble the ductwork sections . > The ductwork sections will need o be joined together by compressing the Acme seams together Figure 28 . b) Install the ductwork section by placing the first section on the square to round already installed on the exhaust fan and secure with the Tek screws provided .
Install the ductwork with the crimped edge pointing in the direction of the airflow and secure with the TeK screws provided .