Technical specifications
ABC-150
3 Phase, 240Vrms, +10%/-15%, <5% imbalance
Input voltage options
325 A
Currency draw
60Hz (50 Hz available)
Frequency
Requires 150KVA external isolation transformer
Isolation transformer
> 99%
Power factor
< 3% THD; IEEE 519 Compliant
Harmonic distortion
Manual; Remote Operation System (ROS); DCOM Driv er for LabVIEW; C++ and Visual Basic; CAN
Multiple user interfaces
< 0.5 Arms
Current ripple - indepdendent & parallel mode
< 15 Arms
Current ripple - max ripple from load
32 - 95°F (0 - 35°C)
Operating environment - temperature
5-90% non-condensing
Operating environment - humidity
1,334 lbs (605 kg)
Weight
46 x 26 x 55 in. (117 x 65 x 140 cm)
Dimensions (L x W x H)
Operating range Configuration
Voltage (Vdc)
Current (Amps)
Power (kW)
+8 to +420
-265 to +265
-125 to +125
Independent
+420 to +435
-160 to +160
-70 to +70
Optional range
+435 to +445
-90 to +90
-40 to +40
+8 to +420
-530 to +530
-125 to +125
Parallel
+420 to +435
-160 to +160
-70 to +70
Optional range
+435 to +445
-90 to +90
-40 to +40
Accuracy & resolution Measurement
Accuracy (±)
Resolution
250mV or 0.15% of the output voltage
20mV
Voltage
100mA or 0.25% of the reading
20mA
Current independent (2 channels)
200mA or 0.35% of the reading
40mA
Current external parallel (1 channels)