910128_900 EX Spec Sheet

Technical specifications

Independent

Parallel

Multi-unit

900 V 500 A

900 V

900 V

Voltage

1,000 A 250 kW

4,000 A

Current

250 kW

1,000 kW

Power

250 μs (Ethernet)

Command latency

93%

Energy recovery efficiency

±0.05 V or ±0.05% of reading

Measurement error-voltage

±160m A or ±0.05% of reading

Measurement error-current

3 ms*

7 ms*

7 ms*

Rise time voltage - step (0-500v)

0.5 ms*

0.6 ms*

0.9 ms*

Rise time current - step (0-300a)

171 V/ms

89 V/ms

76 V/ms

Slew rate voltage

769 A/ms

1,282 A/ms

1,935 A/ms

Slew rate current

274 kW/ms

500 kW/ms

833 kW/ms

Slew rate power

50 Hz (500 V) 75 Hz (250 V) 175 Hz (500 A)

50 Hz (500 V)

50Hz (500 V)

Tracking bandwidth voltage

150 Hz (700 A)

50Hz (700 A)

Tracking bandwidth current

100 Hz (150 kW)

150 Hz (250 kW)

50Hz (250 kW)

Tracking bandwidth power

Fiber to Ethernet CAN RS-232

10 ms 10 ms 50 ms

Output data sampling

3 Phase, 380, 400 and 480 VAC

Input voltage options (+10%/-15%)

410, 389 and 324 A respectively

Current draw

6,063 lbs. (2,750 kg)

Weight

72 x 39 x 76.5 in. (183 x 99 x 194 cm)

Dimensions (L x W x H)

Operating Range Configuration

Voltage (Vdc)

Current (Adc)

Power (kW)

+8 to +750

-500 to +500

-250 to +250

Independent

+751 to +825

-400 to +400

-225 to +225

+826 to +900

-300 to +300

-200 to +200

+8 to +750

-1000 to +1000

-250 to +250

Parallel

+751 to +825

-800 to +800

-225 to +225

+826 to +900

-600 to +600

-200 to +200

The 900 EX can run all standard drive cycle simulations, including FUDS, SFUDS, GSFUDS, DST, ECE-ISL, etc.

Touchscreen HMI for local control & easy identification of operating state.

Webasto Thermo & Comfort North America, Inc. 15083 North Road Fenton, Michigan 48430 USA Toll Free: 800-860-7866 Phone: 810-593-6000 evtestsystems.com

PTS Brochure

evtestsystems.com

Made with FlippingBook Online newsletter