Technical specifications
Independent
Parallel
Multi-unit
900 V 500 A
900 V
900 V
Voltage
1,000 A 250 kW
4,000 A
Current
250 kW
1,000 kW
Power
250 μs (Ethernet)
Command latency
93%
Energy recovery efficiency
±0.05 V or ±0.05% of reading
Measurement error-voltage
±160m A or ±0.05% of reading
Measurement error-current
3 ms*
7 ms*
7 ms*
Rise time voltage - step (0-500v)
0.5 ms*
0.6 ms*
0.9 ms*
Rise time current - step (0-300a)
171 V/ms
89 V/ms
76 V/ms
Slew rate voltage
769 A/ms
1,282 A/ms
1,935 A/ms
Slew rate current
274 kW/ms
500 kW/ms
833 kW/ms
Slew rate power
50 Hz (500 V) 75 Hz (250 V) 175 Hz (500 A)
50 Hz (500 V)
50Hz (500 V)
Tracking bandwidth voltage
150 Hz (700 A)
50Hz (700 A)
Tracking bandwidth current
100 Hz (150 kW)
150 Hz (250 kW)
50Hz (250 kW)
Tracking bandwidth power
Fiber to Ethernet CAN RS-232
10 ms 10 ms 50 ms
Output data sampling
3 Phase, 380, 400 and 480 VAC
Input voltage options (+10%/-15%)
410, 389 and 324 A respectively
Current draw
6,063 lbs. (2,750 kg)
Weight
72 x 39 x 76.5 in. (183 x 99 x 194 cm)
Dimensions (L x W x H)
Operating Range Configuration
Voltage (Vdc)
Current (Adc)
Power (kW)
+8 to +750
-500 to +500
-250 to +250
Independent
+751 to +825
-400 to +400
-225 to +225
+826 to +900
-300 to +300
-200 to +200
+8 to +750
-1000 to +1000
-250 to +250
Parallel
+751 to +825
-800 to +800
-225 to +225
+826 to +900
-600 to +600
-200 to +200
The 900 EX can run all standard drive cycle simulations, including FUDS, SFUDS, GSFUDS, DST, ECE-ISL, etc.
Touchscreen HMI for local control & easy identification of operating state.
Webasto Thermo & Comfort North America, Inc. 15083 North Road Fenton, Michigan 48430 USA Toll Free: 800-860-7866 Phone: 810-593-6000 evtestsystems.com
PTS Brochure
evtestsystems.com
Made with FlippingBook Online newsletter