Technical specifications
ABC-170
ABC-170 CE
3 Phase, 240 VAC
3 Phase, 400, 415 and 480 VAC
Input voltage options
340 A
203, 195, and 170 A respectively
Currency draw
60 Hz (50 Hz available)
50 Hz (60 Hz optional)
Frequency
Requires external isolation transformer with 225KVA, 240Vrms secondary
Internal transformer
Isolation transformer
> 99%
> 99%
Power factor
< 3% THD; IEEE 519 Compliant
< 3% THD; IEEE 519 Compliant
Harmonic distortion
Manual; Remote Operation System (ROS); DCOM Driver for LabVIEW; C++ and Visual Basic; CAN
Manual; Remote Operation System (ROS); DCOM Driver for LabVIEW; C++ and Visual Basic; CAN
Multiple user interfaces
< 0.5Arms
< 0.5Arms
Current ripple - indepdendent & parallel mode
< 15Arms
< 15Arms
Current ripple - max ripple from load
32 - 95°F (0 - 35°C)
32 - 95°F (0 - 35°C)
Operating environment - temperature
5-90% non-condensing
5-90% non-condensing 3,925 lbs. (1,780 kg) 73 x 30 x 71 in. (183 x 76 x 180 cm)
Operating environment - humidity
1,334 lbs. (605 kg)
Weight
46 x 26 x 55 in. (117 x 65 x 140 cm)
Dimensions (L x W x H)
Operating range Configuration
Voltage (Vdc)
Current (Adc)
Power (kW)
+8 to +420
-320 to +265
-170 to +125
Independent
+420 to +435
-160 to +160
-70 to +70
Optional range
+435 to +445
-90 to +90
-40 to +40
+8 to +420
-640 to +530
-170 to +125
Parallel
+420 to +435
-160 to +160
-70 to +70
Optional range
+435 to +445
-90 to +90
-40 to +40
Accuracy & resolution Measurement
Accuracy (±)
Resolution
250mV or 0.15% of the output voltage
20mV
Voltage
100mA or 0.25% of the reading
20mA
Current independent (2 channels)
200mA or 0.35% of the reading
40mA
Current external parallel (1 channels)
Webasto Thermo & Comfort North America, Inc. 15083 North Road Fenton, Michigan 48430 USA Toll Free: 800-860-7866 Phone: 810-593-6000 evtestsystems.com
PTS Brochure
evtestsystems.com