Clean-Resources-Super-PAK-sell-sheet

SUPER-PAK | SERIES 1 – 4 | SP PUMP

New Timer Drain All new Super Series Oil-Water Separators come equipped with

We’re Here to Help! Need a custom solution to fit your specific needs? No problem! Clean Resources works with distributors and end-users to engineer and test specific requirements on a client-by-client basis. One example, a client needed to monitor and test water samples regularly. On all of their Super-Pak 4 units, a designated test port was added between units 3 and 4 and another at the outlet hub. Have a special request? Give us a call! Product Installation and Recycling Most Clean Resources products are shipped with printed installation instructions attached to the unit or printed on the label. We know they get tossed out, “lost,” or sometimes you’d just rather not read the instructions. Not to worry. Each unit’s product label has a QR code that takes you to our installation series of videos. Here you can watch Jerry, our Clean Resources installation expert, talk you through installation and recycling, step-by-step. You will be up and running in no time, and EPA compliant.

a timer drain. This drain prevents the formation of a sludge mat that can occur in a small number of applications. Super-Paks arrive with the timer drain already installed. All you need to do is connect a clean shop air source and plug in the timer drain.

For full installation instructions, go to CleanResources.com/Super-series-video.html

Product Specifications

SUPER-PAK

HP ACFM

1

2

3

4

Works With ALL Compressor Lubricants

Unit Life in Hours* †

150 30,000 200 1,000 22,000 33,000 250 1,250 18,000 27,000 300 1,500 14,000 750

Diester-based PAO-based POE-based Glycol-based

Mineral-based

Quincy

Anderol

Atlas Copco

Ultra Chem

Sullivan-Palatek

21,000 35,000 18,000 29,000 15,000 25,000

350 1,750 12,000 400 2,000 10,000

Summit

Compair

Hydraulic

Gardner Denver

Ingersoll-Rand

450 2,250 500 2,500 600 3,000 800 4,000 1000 5,000 1200 6,000 1400 7,000 1600 8,000 1800 9,000 2000 10,000

9,000 9,000 7,000 6,000 4,000 4,000

14,000 24,000 33,000 13,000 22,000 31,000 11,000 18,000 26,000 8,000 14,000 19,000 7,000 11,000 16,000

Food grade

Kaeser

Sullair

Width (in)

Depth (in)

Height (in)

Weight (lbs)

Unit

6,000 5,000 4,000 4,000

9,000 13,000 8,000 11,000 7,000 10,000

Super-Pak 1 32 Super-Pak 2 40 Super-Pak 3 48 Super-Pak 4 48

52 48 48 48 15

45 45 45 45 31

750

6,000 6,000

9,000 8,000

1,500 2,250 3,000

* Unit life numbers in this chart assume rotary screw compressors with 2 ppm oil carryover running 8,000 hrs/yr. Unit life may vary due to differences in air compressor oil consumption rates, age, and maintenance of compressor. For use with reciprocating compressors, consult factory to calculate unit life.

SP-Pump*

15

21

CORRECTION FACTORS ROTARY SCREW COMPRESSORS (2 ppm carryover) Unit Life: [hours from above] x [CF from right] Example: Super-Pak 3 at 450 hp running 8,000 hrs/yr Unit Life: 24,000 x 1 = 24,000 hours †

* SP-Pump is enclosed in a 15-gallon container and requires 110 volts on a non-GFI outlet

Hrs/yr runtime Life Correction Factor (CF)

8,000 6,000 4,000 2,000

1 1.33 2

4

† To calculate unit life in months: [Unit Life] / 8,000 * 12

Clean Resources | 1540 Louis Bork Drive, Batavia, IL 60510 | 800-566-0402 | cleanresources.com

v14.1 2-18-2025