Catalog MIL-DTL-38999 Series & derivates

Amphenol SOCAPEX │ MIL-DTL-38999 SERIES │ Series III TV-CTV

MIL-DTL-38999 SERIES III DERIVED RANGE - POWERSAFE - VG96944

Amphenol Power Safe range offers 7 contact arrangements to fit all your power needs, with single-phase & three-phase layouts, and a choice of 2 insert materials for each layout depending on the need : → E inserts : using the same material than Amphenol Socapex 38999 series connectors and able to whistand a temperature up to 200°C, its CTI is ≤ 100V. Dielectric Withstanding Voltage (DWV) limit have been tested on E inserts in accordance with test procedure EIA-364-20F with maximum voltage applied of 4500 V RMS . → V inserts : developped according to VG96944 standard with a material less impacted by the disconnection under load (avoid arching when disconnecting under load). Able to withstand a maximum temperature of 150°C & have a CTI ≤ 400V (Material Group II according to DIN EN60664-1 (VDE 0110-1):2008-01,4.8.1.3). V inserts have been tested according to VG96944 and DWV limit have been set up to 2500 V RMS .

Single-Phase Layouts

E insert V insert

13-E4 13-V4

15-E4 15-V4

21-E4 21-V4

23-E4 23-V4

Pilot contact (P)

1 Size 20 2 Size 16 1 Size 16

1 Size 16 2 Size 12 1 Size 12

1 Size 16 2 Size 6 1 Size 6

1 Size 16 2 Size 4 1 Size 4

Phase & neutral (N & L)

Protective contact

Pilot contact - P

Phase, Neutral and Protective contact - N, L &

DWV (V RMS ) *

Contact Arrangements

Contact rating (A)

Operating Voltage (V RMS )

Contact rating (A)

Operating Voltage (V RMS )

13-E4 15-E4 21-E4 23-E4 13-V4 15-V4 21-V4 23-V4

0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5

60 60 60 60 60 60 60 60

16 25 63 84 16 25 63 84

1000 1000 1000 1000

3300 3300 3300 3300 1500 1500 2500 2500

250 250 500 500

Three-Phase Layouts

E insert V insert

17-E6 17-V6

23-E6 23-V6

25-E6 25-V6

Pilot contact (P)

1 Size 16 4 Size 12 1 Size 12

1 Size 16 4 Size 8 1 Size 8

1 Size 16 4 Size 6 1 Size 6

Phase & neutral (N & L)

Protective contact

Phase, Neutral and Protective contact - N, L1, L2, L3 &

Pilot contact - P

DWV (V RMS ) *

Contact Arrangements

Contact rating (A)

Operating Voltage (V RMS )

Contact rating (A)

Operating Voltage (V RMS )

17-E6 23-E6 25-E6 17-V6 23-V6 25-V6

0,5 0,5 0,5 0,5 0,5 0,5

60 60 60 60 60 60

25 47 63 25 47 63

1000 1000

3300 3300 2500 2500 2500 2500

500 500 500 500

* : Test voltage in mated condition for Phase, Protective and Neutral pin & socket contacts, and Pilot pin contacts. Test voltage in unmated condition for Pilot socket contact only.

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Amphenol SOCAPEX

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

114