Catalog MIL-DTL-38999 Series & derivates

Amphenol SOCAPEX │ MIL-DTL-38999 SERIES │ Series III TV-CTV

MIL-DTL-38999 SERIES III DERIVED RANGE - POWERSAFE - VG96944

Amphenol Power Safe range offers 7 contact arrangements to fit all your power needs, with single-phase & three-phase layouts, and a choice of 2 insert materials for each layout depending on the need : → E inserts : using the same material than Amphenol Socapex 38999 series connectors and able to whistand a temperature up to 200°C, its CTI is ≤ 100V. Dielectric Withstanding Voltage (DWV) limit have been tested on E inserts in accordance with test procedure EIA-364-20F with maximum voltage applied of 4500 V RMS . → V inserts : developped according to VG96944 standard with a material less impacted by the disconnection under load (avoid arching when disconnecting under load). Able to withstand a maximum temperature of 150°C & have a CTI ≤ 400V (Material Group II according to DIN EN60664-1 (VDE 0110-1):2008-01,4.8.1.3). V inserts have been tested according to VG96944 and DWV limit have been set up to 2500 V RMS .

Single-Phase Layouts

E insert V insert

13-E4 13-V4

15-E4 15-V4

21-E4 21-V4

23-E4 23-V4

Pilot contact (P)

1 Size 20 2 Size 16 1 Size 16

1 Size 16 2 Size 12 1 Size 12

1 Size 16 2 Size 6 1 Size 6

1 Size 16 2 Size 4 1 Size 4

Phase & neutral (N & L)

Protective contact

Pilot contact - P

Phase, Neutral and Protective contact - N, L &

DWV (V RMS ) *

Contact Arrangements

Contact rating (A)

Operating Voltage (V RMS )

Contact rating (A)

Operating Voltage (V RMS )

13-E4 15-E4 21-E4 23-E4 13-V4 15-V4 21-V4 23-V4

0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5

60 60 60 60 60 60 60 60

16 25 63 84 16 25 63 84

1000 1000 1000 1000

3300 3300 3300 3300 1500 1500 2500 2500

250 250 500 500

Three-Phase Layouts

E insert V insert

17-E6 17-V6

23-E6 23-V6

25-E6 25-V6

Pilot contact (P)

1 Size 16 4 Size 12 1 Size 12

1 Size 16 4 Size 8 1 Size 8

1 Size 16 4 Size 6 1 Size 6

Phase & neutral (N & L)

Protective contact

Phase, Neutral and Protective contact - N, L1, L2, L3 &

Pilot contact - P

DWV (V RMS ) *

Contact Arrangements

Contact rating (A)

Operating Voltage (V RMS )

Contact rating (A)

Operating Voltage (V RMS )

17-E6 23-E6 25-E6 17-V6 23-V6 25-V6

0,5 0,5 0,5 0,5 0,5 0,5

60 60 60 60 60 60

25 47 63 25 47 63

1000 1000

3300 3300 2500 2500 2500 2500

500 500 500 500

* : Test voltage in mated condition for Phase, Protective and Neutral pin & socket contacts, and Pilot pin contacts. Test voltage in unmated condition for Pilot socket

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Amphenol SOCAPEX

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex