Catalog MIL-DTL-38999 Series & derivates

Amphenol SOCAPEX │ MIL-DTL-38999 SERIES │ Series III TV-CTV

MIL-DTL-38999 SERIES III DERIVED RANGE - POWERSAFE - VG96944

Main features Reduced flange receptacle are derived from 38999 series III Jam nut receptacles and dedicated for applications where size & weight are criticals, offering un smaller footprint and lower weight.

With Castle nut

- For Jam nut receptacle (TV07/TVS07). - Higher density on panel: 41% average footprint surface reduction. - Lighter: 20% average lighter than standard 38999 - Mates with standard Power Safe plug and caps. - Matches the Power Safe performances. - Improved design of the o’ring groove allowing the o’ring to stay in place.

MATED PAIR

RECEPTACLE FRONT FACE

Standard TV*07***

Jam nut Reduced flange TV*07***F312

Footprint savings Average 41% footprint reduction:

Reduced flange F312

PowerSafe Reduced flange (F312) ØB MAX (mm)

Standard

Standard PowerSafe ØA MAX (mm)

Size

Ø Reduction

13 15 17 21 23 25

38.4 41.6 44.8 52.7 55.9

28.1 32.1 36.1 41.1 44.1 48.1

46% 40% 35% 39% 38% 34%

59

All others dimensions remains the same in standard or reduced flange (lengths, threads, etc.).

Panel hole dimensions

ØG +0.1 0

H +0.1 0 22.3 25.5 30.3 35.1 38.3 41.5

E recommended

Size

13 15 17 21 23 25

31.4 34.5 37.7 43.7 46.9 51.0

23 27 31 36 39 43

Tooling

Specific tool for castle nut

Size

Tool reference

13 15 17 21 23 25

809683 809684 809685 809687 809688 809689

All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch

Amphenol SOCAPEX

Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex

120