Amphenol
Coaxial Contacts
SHIELDED COAXIAL CONTACT
TYPICAL COAXIAL CONTACT INSTALLATION INSTRUCTIONS
Picture
Process
Check
Tools
Strip the jacket slide the piggy back grommet and crimping ferule
Do not damage the braid
Blade
Do not damage the inner conductor
Trim shield strip cable core
Blade
Position nut on retainer as illustrated flare shield and slide nut and retainer assembly under the cable shield until retainer bottoms against braid
The inner conductor shall be visible thru the inspection hole
M22520/2-01 with positionner M22520/2- 31 (5)
Slide inner pin contact over cable center conductor crimp inner conductor
Slide nut and retainer assembly forward until retainer flush with edge of cable core crimp shield crimp sleeve and observe a 0,25 and 1,3mm dimension
Nut must be rotate freely after crimping sleeve
M22520/5-01 with die M22520/5-37 (B)
Expander tool bendix p/n 11- 10136 or equivalent rod bendinx p/n 11-10135 or equivalent
Slide rear insulator using expander tool. slide tool over inner pin contact. Push rear insulator with push rod until it seats between retainer end and inner pin contact shoulder
Snap rear insulator behind inner contact shoulder slide fron insulator until the inner contact flange
Slide outer socket contact over inner pin assembly and insulator thread nut into rear of outer pin contact tighten nut until metal to metal ( 0,21 - 0,25N.m)
Do not allow the cable to rotate while tightening the nut
Coaxial Contacts
25