Catalog Contacts for connectors

Amphenol

Coaxial Contacts

SHIELDED COAXIAL CONTACT

TYPICAL COAXIAL CONTACT INSTALLATION INSTRUCTIONS

Picture

Process

Check

Tools

Strip the jacket slide the piggy back grommet and crimping ferule

Do not damage the braid

Blade

Do not damage the inner conductor

Trim shield strip cable core

Blade

Position nut on retainer as illustrated flare shield and slide nut and retainer assembly under the cable shield until retainer bottoms against braid

The inner conductor shall be visible thru the inspection hole

M22520/2-01 with positionner M22520/2- 31 (5)

Slide inner pin contact over cable center conductor crimp inner conductor

Slide nut and retainer assembly forward until retainer flush with edge of cable core crimp shield crimp sleeve and observe a 0,25 and 1,3mm dimension

Nut must be rotate freely after crimping sleeve

M22520/5-01 with die M22520/5-37 (B)

Expander tool bendix p/n 11- 10136 or equivalent rod bendinx p/n 11-10135 or equivalent

Slide rear insulator using expander tool. slide tool over inner pin contact. Push rear insulator with push rod until it seats between retainer end and inner pin contact shoulder

Snap rear insulator behind inner contact shoulder slide fron insulator until the inner contact flange

Slide outer socket contact over inner pin assembly and insulator thread nut into rear of outer pin contact tighten nut until metal to metal ( 0,21 - 0,25N.m)

Do not allow the cable to rotate while tightening the nut

Coaxial Contacts

25

Made with FlippingBook Learn more on our blog