Amphenol
Concentric Twinax Contacts
TYPICAL CONTACTS INSTALLATION INSTRUCTIONS FOR TWINAX CONTACTS
PICTURE
PROCESS
CHECK
TOOLS
Strip the jacket
Do not damage the braid
Slide the piggy back grommet and crimping ferule
Blade
The braid shall coiver equally the crimping ferule
Open the braid over the crimping ferule
Strip the inner conductors
Do not damage the inner conductors
Blade
Insert the white jacket inner conductor into the inner contact and crimp
The inner conductor shall be visible thru the inspection hole
M22520/2-01 with positionner
Insert the crimp inner contact into the center hole and insert the blue inner conductor in the intermediate contact crimp the intermediate contact
The inner conductor shall be visible thru the inspection hole
M22520/5-01 with correct die
Push the sub assembly into the outer contact when nice installed, cut the additional braid
Do not damage the crimping ferule
Blade
M22520/5-01 with correct die
Crimp the outer contact
Concentric Twinax Contacts
38
Made with FlippingBook Learn more on our blog