Catalog Contacts for connectors

Amphenol

Concentric Twinax Contacts

TYPICAL CONTACTS INSTALLATION INSTRUCTIONS FOR TWINAX CONTACTS

PICTURE

PROCESS

CHECK

TOOLS

Strip the jacket

Do not damage the braid

Slide the piggy back grommet and crimping ferule

Blade

The braid shall coiver equally the crimping ferule

Open the braid over the crimping ferule

Strip the inner conductors

Do not damage the inner conductors

Blade

Insert the white jacket inner conductor into the inner contact and crimp

The inner conductor shall be visible thru the inspection hole

M22520/2-01 with positionner

Insert the crimp inner contact into the center hole and insert the blue inner conductor in the intermediate contact crimp the intermediate contact

The inner conductor shall be visible thru the inspection hole

M22520/5-01 with correct die

Push the sub assembly into the outer contact when nice installed, cut the additional braid

Do not damage the crimping ferule

Blade

M22520/5-01 with correct die

Crimp the outer contact