Amphenol
Quadrax Contacts
QUADRAX CONTACTS FOR SUBMINIATURE
TYPICAL CONTACTS INSTALLATION INSTRUCTIONS FOR QUADRAX CONTACTS
Picture
Process
Check
Tools
Strip the jacket
Do not damage the braid
Slide the piggy back grommet and crimping ferule
Blade
The braid shall coiver equally the crimping ferule
Open the braid over the crimping ferule
Blade (To Trim Excess Braid)
Strip the inner conductors
Do not damage the inner conductors
Blade
The inner conductor shall be visible thru the inspection hole
Crimp the inner contacts
M22520/2-01 with positionner M22520/2-37
Install the rear insulator and respect the circular location for each individual contact
The contact location shall respect circular location
Slide the front insulator over the contact by the front
The keyway orientation shall meet the key way in outer contact
M22520/5-01 with M22520/5-45(A)
Crimp the outer contact
Quadrax Contacts
44