PLAIN TALL PILASTERS
FLUTED TALL PILASTERS
PP1.584T PP1.584T27 PP1.587T PP1.587T27 PP1.590T PP1.590T27 PP1.593T PP1.593T27 PP1.596T PP1.596T27 PP1.5102T PP1.5102T27
PP684T PP684T27 PP687T PP687T27 PP690T PP690T27 PP693T PP693T27 PP696T PP696T27 PP6102T PP6102T27
FP84T FP84T27 FP87T FP87T27 FP90T FP90T27 FP93T FP93T27 FP96T FP96T27 FP102T FP102T27
FP684T FP684T27 FP687T FP687T27 FP690T FP690T27 FP693T FP693T27 FP696T FP696T27 FP6102T FP6102T27
PP84T PP84T27 PP87T PP87T27 PP90T PP90T27 PP93T PP93T27 PP96T PP96T27 PP102T PP102T27
2 3 / 4
84, 87, 90, 93, 96, 102
84, 87, 90, 93, 96, 102
7 1 / 2
• ¾ ” Solid wood fronts • Back, top and bottom are ½” unfinished plywood • Sides are ½” finished plywood • 3” wide has 4 flutes and 6” wide has 8 flutes • When ID/RD option is chosen, pilasters are built to the specified depth (i.e. RD16 will be 16” deep) • For MDF door styles, pilasters are painted hardwood
• ¾ ” Solid wood fronts • Back, top and bottom are ½” unfinished plywood • Sides are ½” finished plywood • When ID/RD option is chosen, pilasters are built to the specified depth (i.e. RD16 will be 16” deep) • Finish techniques are not included • For MDF door styles, pilasters are painted hardwood
25, 28
3, 6
25, 28
1 3, 6 1 / 2 ,
WIDTH
HEIGHT
DEPTH
WIDTH
HEIGHT
DEPTH
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Modification APC BO CC ES FCE FDBS FH FI FIMD FO ID IF IME MFE MD MH MW P PCE RD RTK TKA VTK WBR WCM WS WTR FOL/TOL s s • s • INS s s • s •
Modification APC BO CC ES FCE FDBS FH FI FIMD FO ID IF IME MFE MD MH MW P PCE RD RTK TKA VTK WBR WCM WS WTR FOL/TOL s s • s • INS s s • s •
ANGLE PLAIN TALL PILASTERS
APP84TL APP84TR
APP93TL APP93TR
24, 27
21, 24
APP84T27L APP84T27R
APP93T27L APP93T27R
24
27
APP87TL APP87TR
APP96TL APP96TR
APP87T27L APP87T27R
APP96T27L APP96T27R APP102TL APP102TR APP102T27L APP102T27R
84, 87, 90, 93, 96, 102
3
Top View
APP90TL APP90TR
APP90T27L APP90T27R
21
24
3
• ¾ ” Solid wood fronts • Back, top and bottom are ½” unfinished plywood
3
Top View
Left Shown
• Finished on front and short side only • Short side available with FCE option • When ID/RD option is chosen, pilasters are built to the specified depth (i.e. RD16 will be 16” deep) • Finish techniques are not included • For MDF door styles, pilasters are painted hardwood • INSET: Not available
WIDTH
HEIGHT
DEPTH
Min.
Max.
Min.
Max.
Min.
Max.
Modification APC BO CC ES FCE FDBS FH FI FIMD FO ID IF IME MFE MD MH MW P PCE RD RTK TKA VTK WBR WCM WS WTR FOL/TOL s • • s •
Premier– 5–15
Made with FlippingBook Online document maker