5.4 Removing Shipping Retainers
AVR systems are shipped with multiple mechanisms to prevent movement during shipment. The following information describes the various retainers. Refer to the following figures for locations of these retainers.
Carrying Handles
To remove the carrying handles, refer to the following figure and perform the following steps:
1. Locate the two red carrying handles near the back of the base. The carrying handles can be removed or be left on the system following installation to facilitate possible later lifting.
2. Locate the lift bar toward the front of the base. This bar is used to secure the units in their shipping crate and can also be used for lifting. The bar is normally removed once the system is installed.
3. Slide the bar out to remove it from the system.
4. Remove any tape and packing materials that might have been added for shipment.
Figure 20. Location of Red Retainer Tab, Lifting Handles, and Slider Bar