KMR Manual

7.5 Electrical Connections

Brick type AC power adapters for PC (top) and metrology unit (bottom)

 Power to the metrology unit is via a brick type AC adapter with 100/240 Vac input and 24 Vdc, 5A output.  Power to the Shuttle PC is via via a brick type AC adapter with 100/240 Vac input and 19 Vdc, 4.74A output.  Power to the XGA monitor is directly via an AC cable.  XGA systems use a VGA cable from the metrology unit to the video monitor.  PC-based systems with MetLogix software use three USB cables to connect the Shuttle PC to: 1) the camera of the metrology unit, 2) the MetLogix control unit, and 3) the 24” touch- screen monitor  Power to the wireless mouse is provided by a single AA battery. Have spare AA batteries on hand. There is an on/off switch in back of the mouse. Turn on this switch to use the mouse.  Power to the wireless keyboard is provided by two AAA batteries. Have spare AAA batte- ries on hand. There is an on/off switch on the top of the keyboard. Turn on this switch to use the keyboard.

- 36 -

Made with FlippingBook - professional solution for displaying marketing and sales documents online