OMNIA SURGICAL SUTURES
OMNIA SURGICAL SUTURES | 3
2 | OMNIA SURGICAL SUTURES
MAKE THE RIGHT CHOICE THE RIGHT SUTURE FOR ALL YOUR SURGICAL NEEDS
SURGICAL SUTURES The purpose of the surgical suture (medical device) is to hold body tissues of the surgical wound together until the healing process progresses to such an extent that it is not considered necessary to further support it. Main parts of a surgical suture are the thread and the needle, and a number of different shapes, sizes and thread material have been developed over the last decades. Our goal is to develop and produce the perfect suture for all of your dental procedures. We achieve this by choosing the best suppliers and keeping our production and quality updated with the high standards of Pharmacopeia (US & EP).
MONOFILAMENT VS. MULTIFILAMENT
OMNIA SUTURES
MONOFILAMENT • Encounter less resistance as they pass through tissue • They resist harboring organisms • These characteristics make monofilament sutures well-suited to vascular surgery • Extreme care must be taken when handling and tying these sutures • Crushing or bending of this suture type can create a weak spot in the strand. This may result in suture breakage • Monofilaments usually require more knots to prevent slippage
MULTIFILAMENT • They offer greater tensile strength and flexibility Pliability, easier to handle • Multifilament sutures may be coated to help them pass relatively smoothly through tissue and enhance handling characteristics • Coated multifilament sutures are well-suited to intestinal procedures
ABSORBABLE SYNTHETIC SUTURES • PGA • PGCL • PGLA RAPID
NON ABSORBABLE SYNTHETIC SUTURES
PLURIFILAMENT
MONOFILAMENT
• POLYESTER • POLYAMIDE • POLYPROPYLENE • PTFE
SYNTETIC
BIOLOGICAL
SYNTETIC
NON ABSORBABLE NATURAL SUTURES
• POLYPROPYLENE • POLYAMIDE
• PGA • POLYESTER • PGLA RAPID
• SILK
• PGCL • PTFE
• SILK
OMNIA SURGICAL SUTURES | 5
4 | OMNIA SURGICAL SUTURES
ABSORBABLE VS. NON ABSORBABLE
PRODUCTION: 4 STEPS FOR PERFECT SUTURES
1
2
3
4
ABSORBABLE
NON ABSORBABLE
PRO • Broken down by body. • body left.
PRO • Permanent wound support.
CONTRA • Foreign body left. • Suture removal can be costly and inconvenient. • Sinus & extrusion if left in place.
CONTRA • Consideration of wound support time. • Attention to the absorption time.
CUTTING + TIPPING
ATTACHING PROCESS
QUALITY CONTROL Quality control is introduced in all aspects of production.
PACKAGING + STERILIZATION Medical device packaging and sterilization.
The process of cutting and tipping the surgical sutures.
Surgical sutures attaching machine provides a secure way to attach drilled end needles.
NON ABSORBABLES
ABSORBABLES
BIOLOGICAL
SYNTETIC
SYNTETIC
HOW TO READ THE SUTURE LABEL
• POLIPROPYLENE • POLYAMIDE • POLYESTER • PTFE
• SILK
• PGA • PGCL • PGLA RAPID
Needle drawing and needle point type
Instructions
UDI Code
SYNTHETIC VS. BIOLOGICAL
Brand name
Product name
SYNTHETIC
BIOLOGICAL
Product code
Country of origin
Thread size
Instructions CE number
PRO • Non-absorbable are inert/inactive • Absorbable resemble natural substances
PRO Handling & knotting Economy
Thread length
• Absorption by hydrolysis • Predictable absorption • Strength
Needle length needle curving
Sterilization method
CONTRA Tissues Reaction
Instructions
CONTRA • Monofilament handling
For more informations on all the sutures available please visit: https://www.omniaspa.eu/en/products/surgical-sutures.html
OMNIA SURGICAL SUTURES | 7
6 | OMNIA SURGICAL SUTURES
rcle
1/2 Circle
NEEDLE SHAPES AND ANATOMY
PGLA RAPID SUTURES MULTIFILAMENT – ABSORBABLE SYNTHETIC – UNDYED
NEW
Composed of a copolymer made from 90% glycolide and 10% L-lactide. The special coating offers a great ease of knotting and excellent hold of the knot also has a low bacterial adhesion. Suture absorption will be completed in 42 days by hydrolysis. The hold of the suture will be 50% of the total after 5 days and total loss between 10 to 14 days. Thanks to the non-need to remove the stitches, it is a very versatile suture that lends itself to multiple uses in the field of oral surgery.
rcle
1/2 Circle
3/8 Circle
Body Length Point: the sharpened part of the needle that first penetrates the tissue. The point consist of the area from the sharpened tip of the needle to the widest cross section of the needle body. The point determines ease of penetration and the initial size and shape of the hole. Wire Diameter Swage Length: distance measured along the circumference of the needle, from the point to the swage. It is depicted on the packaging. Shape: different surgeries or surgical techniques demand different needle shapes. Point
Point
Swage
Body
Wire Diameter
CHARACTERISTICS: • Smooth passage through tissue • Easy knotting • Minimal inflammatory reaction • Low memory
Length
3/8 Circle
Swage Swage: Connection point of the suture and the needle. Wire Diameter: gauge or thickness of the wire originally used to form the needle body. Body: the part between the point and the swage of the needle. Curvature: the fraction of the circle included in the curve of the needle. Point
APPLICATION: • Multiple uses in the field of oral surgery when short-term support is needed.
Body
NEEDLE POINTS AND CUTTING EDGES
Wire Diameter
Length
Thread size Needle type
Point type Needle length Needle curving Wire length Code
Pcs./box
Needle type Point geometry Description
Commonly used for
Due to its cutting edges, this needle easily penetrates tissues and is suitable for almost all uses. It provides an excellent penetration capacity and great solidity, and is fit for sutures with periosteum incision and in case of thick mucosa.
4/0
32.Z3450.00
Reverse Cutting
16 mm
3/8 circle
75 cm
12
Reverse Cutting
Oral surgery Exodontia
5/0
32.Z3451.00
Reverse Cutting
16 mm
3/8 circle
75 cm
12
5/0
32.Z3452.00
Extra Reverse Cutting
12 mm
3/8 circle
45 cm
12
Extra Reverse Cutting
Indictated for hard tissue, extra cutting needle has very sharp edge for good penetration and less trauma.
Microsurgery Periodontal
6/0
32.Z3453.00
Extra Reverse Cutting
12 mm
3/8 circle
45 cm
12
5/0
32.Z3454.00
Reverse Cutting
12 mm
1/2 circle
75 cm
12
Quadrangular pyramid-shaped point and a round body. This particular shape allows any easy penetration of soft tissues without causing lacerations, and preventing the needle from rotating in the needle-holder. This needle is appreciated and suitable for oral surgery. Mainly used for soft tissues, and is characterized by a good penetration of tissues without causing lacerations or tissue damage.
Implantology Mucogingival
6/0
32.Z3455.00
Reverse Cutting
12 mm
1/2 circle
75 cm
12
Taper Cut
Soft tissue Tissue infected
Round Body
OMNIA SURGICAL SUTURES | 9
8 | OMNIA SURGICAL SUTURES
PGA SUTURES MULTIFILAMENT - ABSORBABLE SYNTHETICS - VIOLET
PGCL SUTURES MONOFILAMENT - ABSORBABLE SYNTHETICS - VIOLET
PGA sutures have synthetic origin and are made with a multi-thread consisting of braided Polyglycolic Acid, coated with a layer of Polycaprolactone copolymer. The woven structure offers a great ease of knotting and excellent hold of the knot also has a low bacterial adhesion. Suture resorption will be completed between the fiftieth and ninetieth day. The hold of the suture will be 65% of the total after 2 weeks and 35% of the total at the end of the third week. Thanks to the non-need to remove the stitches, it is a very versatile suture that lends itself to multiple uses in the field of oral surgery.
Composed of a copolymer of Polyglycolic acid and Polycaprolactone. In periodontal surgery its monofilament characteristics allow for less plaque retention. The progressive loss of tensile strength and suture absorption occurs by hydrolysis, in which the polymer degrades in to a dipic acid which is subsequently absorbed and metabolized by the tissues. Absorption begins as loss of tensile strength with out appreciable loss of mass. PGCL suture retention is 68-78% of the initial tensile strength after the first week and about 30% after the end of the second week. Suture absorption is essentially complete after a period of 90-110 days. Its original tensile strength is up to 14 days and runs out after 28 days.
CHARACTERISTICS: • Easy to knot and excellent knot stability • Low microbial load APPLICATION: Very versatile suture that lends itself to multiple uses in the field of oral surgery.
CHARACTERISTICS: • Extremely manageable and smooth • Low memory • God knotting • Minimal inflammatory reaction
APPLICATION: • Flaps • Regenerationy • Implants • Mucogingival Surgery • Oral Surgery
Thread size Needle type
Point type Needle length Needle curving Wire length Code
Pcs./box
3/0
32.Z3057.00
Reverse Cutting
19 mm
3/8 circle
75 cm
24
4/0
32.Z3063.00
Reverse Cutting
16 mm
3/8 circle
75 cm
24
4/0
32.Z3059.00
Reverse Cutting
19 mm
3/8 circle
75 cm
24
4/0
32.Z3066.00
Taper Cut
17 mm
1/2 circle
75 cm
24
Thread size Needle type
Point type Needle length Needle curving Wire length Code
Pcs./box
5/0
32.Z3070.00
Reverse Cutting
12 mm
1/2 circle
75 cm
24
4/0
32.Z3300.00
Reverse Cutting
16 mm
3/8 circle
75 cm
12
5/0
32.Z3056.00
Reverse Cutting
16 mm
3/8 circle
75 cm
24
5/0
32.Z3301.00
Extra Reverse Cutting
12 mm
3/8 circle
45 cm
12
5/0
32.Z3062.00
Extra Reverse Cutting
12 mm
3/8 circle
45 cm
12
5/0
32.Z3302.00
Reverse Cutting
16 mm
3/8 circle
75 cm
12
New
6/0
32.Z3061.00
Extra Reverse Cutting
12 mm
3/8 circle
45 cm
12
6/0
32.Z3304.00
Extra Reverse Cutting
12 mm
3/8 circle
45 cm
12
New
6/0
32.Z3064.00
Extra Reverse Cutting
10 mm
3/8 circle
45 cm
12
4/0
32.Z3303.00
Reverse Cutting
19 mm
3/8 circle
75 cm
12
7/0
32.Z3067.00
Extra Reverse Cutting
7 mm
1/2 circle
45 cm
12
7/0
32.Z3065.00
Extra Reverse Cutting
10 mm
3/8 circle
45 cm
12
OMNIA SURGICAL SUTURES | 11
10 | OMNIA SURGICAL SUTURES
POLYESTER SUTURES MULTIFILAMENT - NON ABSORBABLE SYNTHETIC - GREEN
POLYAMIDE SUTURES MONOFILAMENT - NON ABSORBABLE SYNTHETIC - LIGHT BLUE
Polyester is a non-absorbable multifilament su- ture, which is made of polyethylene terephthal- ate (PET), a biologically inert material causing minimal tissue reaction. Fibers are dyed in green with D&C Green No. 6 coloring agent. The suture is coated with silicone to make its surface smoother and uniform. It is characterized by a higher tensile strength than silk and a reduced risk of tissue reactions.
Polyamide is a synthetic material which makes it possible to produce high quality non-absorbable monofilament sutures. The suture features a smooth, even surface, it is easy to handle and the monofilament has a low memory. The biological behavior envisages a negligible tissue reaction, while the lack of bacterial adhesion and high resistance even with small diameters makes this suture ideal for all implant and periodontal procedures. The excellent quality price ratio extends its use to small extractive surgery.
CHARACTERISTICS: • Excellent gliding through the tissues • Easy to knot and excellent knot stability • Negligible bacterial adhesion • Excellent elasticity
APPLICATION: • Flaps • Regenerationy • Implants • Mucogengival Surgery • Oral Surgery
Thread size Needle type
Point type Needle length Needle curving Wire length Code
Pcs./box
CHARACTERISTICS: • Excellent initial and prolonged durability • Low risk of reactions – Biocompatible • Strong knotting • Easy and flexible thread
32.Z4622.00
4/0
Reverse Cutting
16 mm
3/8 circle
75 cm
24
32.Z4623.00
4/0
Reverse Cutting
17 mm
1/2 circle
75 cm
24
32.Z4611.00
4/0
Reverse Cutting
12 mm
3/8 circle
75 cm
24
32.Z4621.00
4/0
Reverse Cutting
16 mm
3/8 circle
75 cm
24
32.Z4620.00
6/0
Reverse Cutting
16 mm
3/8 circle
75 cm
24
APPLICATION: • Oral Surgery
POLYPROPYLENE SUTURES MONOFILAMENT - NON ABSORBABLE SINTHETICS - BLUE
Polypropylene is a synthetic, non-absorbable monofilament suture. It is particularly biocompatible with the tissues with easy removal from the patient. Because it does not degrade and does not attenuate, it offers a high resistance to the tissue compaction. Also due to its monofilament property it is indicated for use in areas prone to bacteria.
Thread size Needle type
Point type Needle length Needle curving Wire length Code
Pcs./box
CHARACTERISTICS: • Easily tissue penetration • Secured knots • High tensile strength • Low microbial load • Low tissue reaction
APPLICATION: • Flaps • Regenerationy • Implans • Mucogengival Surgery • Oral Surgery
32.Z3006.00
3/0
Reverse Cutting
19 mm
3/8 circle
75 cm
24
32.Z3001.00
3/0
Taper Cut
17 mm
1/2 circle
75 cm
24
32.Z3003.00
4/0
Reverse Cutting
12 mm
3/8 circle
75 cm
24
32.Z3004.00
4/0
Reverse Cutting
16 mm
3/8 circle
75 cm
24
32.Z3005.00
4/0
Reverse Cutting
19 mm
3/8 circle
75 cm
24
Thread size Needle type
Point type Needle length Needle curving Wire length Code
Pcs./box
32.Z3002.00
4/0
Taper Cut
17 mm
1/2 circle
75 cm
24
32.Z3100.00
4/0
Reverse Cutting
16 mm
3/8 circle
75 cm
24
32.Z3007.00
5/0
Taper Cut
18 mm
3/8 circle
75 cm
24
32.Z3102.00
5/0
Reverse Cutting
12 mm
3/8 circle
75 cm
24
32.Z3008.00
6/0
Taper Cut
18 mm
3/8 circle
75 cm
24
32.Z3101.00
5/0
Reverse Cutting
16 mm
3/8 circle
75 cm
24
32.Z3009.00
6/0
Extra Reverse Cutting
12 mm
3/8 circle
45 cm
12
32.Z3103.00
6/0
Extra Reverse Cutting
12 mm
3/8 circle
45 cm
12
OMNIA SURGICAL SUTURES | 13
12 | OMNIA SURGICAL SUTURES
PTFE SUTURES MONOFILAMENT - NON ABSORBABLE WHITE
WHAT DO OUR OPINION LEADERS SAY?
PTFE Surgical Suture (Polytetrafluoroethylene) are ideal for all implant, periodontal and bone grafting procedures where the use of a monofilament suture with low bacterial adhesion is desirable. Unlike other synthetic monofilament sutures, the material is exceptionally well tolerated in the oral cavity.
CHARACTERISTICS: • Particularly soft for the patient • Biologically inert • Excellent Biocompatibility • Chemically non-reactive • No memory • Resistant • Superior fluency in oral tissue
APPLICATION: PTFE suture is indicated for use in all types of soft tissue approximation and/or ligation, including cardiovascular, dental and general surgeries, as well as repair of the dura mater. The device is not indicated for use in ophthalmic surgery, microsurgery and peripheral neural tissue.
The concept for success in periodontal and implant surgery is related to the ability of perfectly performing every single step of the procedure. Starting from this point, the flap design, the line of incision, the split or full-thickness elevation are not the only critical stages of the surgery, but also the management of the soft tissues during the final phases of the operation has to be performed at the best. For this reason, PTFE can be considered as the gold standard for the choice of the suturing material. The perfect tightness of the knot, the sliding, the biocompatibility, the little plaque retention represent basic characteristics during the choice of the suture, and the PTFE has all of them. Their ability to keep the flaps well closed and the incapability to keep the plaque are a plus in the post surgery period, so to limit any possible complication that may occur as the opening of the flaps with separation of the soft tissues or infection on the suture line. For these reasons, our personal preference is for the Omnia PTFE in all the operations of periodontal plastic and regene-rative surgery, ridge preservation and bone regenerative surgery.
Thread size Needle type
Point type Needle length Needle curving Wire length Code
Pcs./box
2/0
32.Z3120.00
Reverse Cutting
19 mm
3/8 circle
75 cm
12
3/0
32.Z3130.00
Reverse Cutting
19 mm
3/8 circle
75 cm
12
4/0
32.Z3141.00
Reverse Cutting
16 mm
3/8 circle
75 cm
12
4/0
32.Z3240.00
Taper Cut
18 mm
3/8circle
75 cm
12
Taper Cut Black needle
4/0
32.Z3143.00
16 mm
3/8 circle
45 cm
12
5/0
32.Z3151.00
Reverse Cutting
12 mm
3/8 circle
75 cm
12
Dr. Daniele Cardaropoli
5/0
32.Z3150.00
Reverse Cutting
12 mm
1/2 circle
75 cm
12
5/0
32.Z3250.00
Taper Cut
18 mm
3/8 circle
75 cm
12
Taper Cut Black needle
5/0
32.Z3152.00
13 mm
3/8 circle
45 cm
12
5/0
32.Z3252.00
Extra Reverse Cutting
12 mm
3/8 circle
45 cm
12
OMNIA sutures are superior in quality and provide me with excellent hanling qualities and ease of flap closure.
6/0
32.Z3160.00
Reverse Cutting
11 mm
1/2 circle
75 cm
12
6/0
32.Z3260.00
Taper Cut
10 mm
1/2 circle
75 cm
12
Dr. Maurice Salama, DMD
6/0
32.Z3161.00
Extra Reverse Cutting
10 mm
3/8 circle
45 cm
12
7/0
32.Z3270.00
Extra Reverse Cutting
10 mm
3/8 circle
45 cm
12
Polyamyde Pharm. EP/Load (N)
Polyamyde Pharm. US/Load (N)
OMNIA SURGICAL SUTURES | 15
14 | OMNIA SURGICAL SUTURES
SILK SUTURES MULTIFILAMENT - NON ABSORBABLE NATURAL - BLACK
THE TENSILE STRENGTH OF OUR SUTURES TENSILE STRENGHT OMNIA POLYAMIDE
TENSILE STRENGHT OMNIA POLYESTER
TENSILE STRENGHT OMNIA POLYESTER
25
25
25
20
20
For a surgeon the selection of a suture material is one of the most important choices. One of the most critical handling characteristics of this material is the strength. The strength of a suture material is important for different reasons, including the ability of the suture to withstand knotting and the imposed stress when used to bring soft tissues close. Sutures of low strength will tend to break during surgery or, more seriously, post-surgery (after surgery). If this happens, the surgeon has to waste time and effort in re-suturing the wound while in the latter case, not closing the wound might cause an infection. The below diagrams show the high tensile strength Omnia sutures have according to the US and European Pharmacopeia. 0 5 10 15 Polyamyde OMNIA/Load (N) Polyamyde Pharm. US/Load (N) Polyamyde Pharm. EP/Load (N) 3/0 4/0 5/0 6/0 Thread size 0 5 10 15 3/0 4/0 5/0 OMNIA/Load (N) Pharm. US/Load (N) Pharm. EP/Load (N) Thread size 0 5 10 15 20 3/0 4/0 5/0 OMNIA/Load (N) Pharm. US/Load (N) Pharm. EP/Load (N) Thread size
Non-absorbable, multifilament suture made from natural silk. The thread has a silicon coating to create a smoother and uniform surface and is dyed black for enhanced visibility. It offers excellent penetration and high strength and is suitable for intersection of the periosteum and in the presence of substantial mucous membranes.
6/0
6/0
TENSILE STRENGTH OMNIA POLYPROPYLENE TENSILE STRENGHT OMNIA POLYPROPYLENE TENSILE STRENGHT OMNIA POLYPROPYLENE
TENSILE STRENGTH OMNIA POLYESTER
TENSILE STRENGHT OMNIA PTFE TENSILE STRENGHT OMNIA POLYESTER
12
12
25 20 25
10
CHARACTERISTICS: • Easy to use and flexible • Secure knots • High tensile strength • Low memory • Low price
10
8
8
20 15
6
6
15 10
4
4
5
2
2
10
0
0
Thread size
0
3/0
4/0
5/0
6/0
Thread size
4/0
5/0
6/0
5
Thread size
4/0
5/0
6/0
OMNIA/Load (N)
Pharm. US/Load (N)
Pharm. EP/Load (N)
7/0 Polypropylene OMNIA/Load (N) Polypropylene Pharm. US/Load (N)
0
APPLICATION: • Oral Surgery
Polypropylene OMNIA/Load (N) Polypropylene Pharm. US/Load (N)
Thread size
2/0
3/0
4/0
5/0
6/0
Polypropylene Pharm. EP/Load (N)
Polypropylene Pharm. EP/Load (N)
PTFE OMNIA/Load (N)
PTFE Pharm. US/Load (N)
PTFE Pharm. EP/Load (N)
TENSILE STRENGHT OMNIA POLYPROPYLENE
12
TENSILE STRENGTH OMNIA POLYAMIDE TENSILE STRENGHT OMNIA POLYAMIDE 10
TENSILE STRENGTH OMNIA SILK TENSILE STRENGHT OMNIA SILK TENSILE STRENGHT OMNIA SILK
Thread size Needle Type
Point Type needle length Needle curving Wire length Code
pcs./box
25 30
8
25 30
25
6
32.Z3013.00
2/0
Taper Cut
22 mm
1/2 Circle
75 cm
24
20
20
20
4
15
15
15
32.Z3021.00
2
2/0
Round Body
22 mm
1/2 Circle
75 cm
24
10
10
10
0
5
Thread size
32.Z3032.00
4/0
5/0
6/0
3/0
Reverse Cutting
16 mm
3/8 circle
75 cm
24
5
5
0
0
3/0
4/0
2/0
5/0
0
Thread size
Polyamyde OMNIA/Load (N) Polyamyde Pharm. US/Load (N) Polypropylene OMNIA/Load (N) Polypropylene Pharm. US/Load (N) 3/0
3/0
4/0
32.Z3034.00
3/0
Reverse Cutting
19 mm
3/8 circle
75 cm
24
4/0
5/0
6/0
2/0
5/0
Thread size
Thread size
OMNIA/Load (N)
Pharm. US/Load (N)
Pharm. EP/Load (N)
Polypropylene Pharm. EP/Load (N)
OMNIA/Load (N)
Pharm. US/Load (N)
Pharm. EP/Load (N)
32.Z3011.00
3/0
Taper Cut
17 mm
1/2 Circle
75 cm
24
Polyamyde Pharm. EP/Load (N)
32.Z3012.00
3/0
Taper Cut
22 mm
1/2 Circle
75 cm
24
32.Z3022.00
3/0
Round Body
17 mm
1/2 Circle
75 cm
24
TENSILE STRENGHT OMNIA SILK
32.Z3020.00
3/0
Round Body
22 mm
1/2 Circle
75 cm
24
TENSILE STRENGTH OMNIA PTFE TENSILE STRENGHT OMNIA PTFE TENSILE STRENGHT OMNIA POLYESTER
25 30
32.Z3030.00
4/0
Reverse Cutting
12 mm
3/8 circle
75 cm
24
25
25
20
20
32.Z3033.00
4/0
Reverse Cutting
16 mm
3/8 circle
75 cm
24
15
20
15
10
32.Z3031.00
4/0
Reverse Cutting
19 mm
3/8 circle
75 cm
24
15
10
5
10 5
0
32.Z3010.00
4/0
Taper Cut
17 mm
1/2 Circle
75 cm
24
3/0
4/0
2/0
5/0
Thread size
0
5 Thread size OMNIA/Load (N)
3/0
4/0 Pharm. US/Load (N)
5/0 Pharm. EP/Load (N)
6/0
32.Z3014.00
4/0
Taper Cut
18 mm
3/8 circle
75 cm
24
OMNIA/Load (N)
Pharm. US/Load (N)
Pharm. EP/Load (N)
0
Thread size
2/0
3/0
4/0
5/0
6/0
7/0
32.Z3023.00
4/0
Round Body
17 mm
1/2 Circle
75 cm
24
PTFE OMNIA/Load (N)
PTFE Pharm. US/Load (N)
PTFE Pharm. EP/Load (N)
For more information or to place an order, call at 00800 48 37 43 39 or visit HuFriedyGroup.eu
Free Call: 00800 48 37 43 39 | Free Fax: 00800 48 37 43 40 E-Mail: info@hu-friedy.eu | Website: HuFriedyGroup.eu @HuFriedyGroupEurope
As some of the products included in this catalogue might not be available in some countries, we invite you to verify the availability of the product with your local authorised dealer or to contact our customer care at the free phone number 00800 48 37 43 39.
Hu-Friedy Mfg. Co., LLC. • European Headquarters • Lyoner Str. 9 • 60528 Frankfurt am Main, Germany • HuFriedyGroup.eu. All company and product names are trademarks of Hu-Friedy Mfg. Co. LLC., its affiliates or related companies, unless otherwise noted. ©2021 Omnia Srl. All rights reserved. 90.L0030.EN – 09/2021.
Page 1 Page 2-3 Page 4-5 Page 6-7 Page 8-9 Page 10-11 Page 12-13 Page 14-15 Page 16Made with FlippingBook Annual report