HE400 Manual

HE400 Operators Manual

3.6

Fitting the Mx200 or Tablet PC or DRO (Figure 4)

1. Fit the bracket to the projector, securing it with the four screws A. Using a 5mm Allen key.

2. Fit the Mx200 to the bracket, securing it with the two screws B. Using a 5mm Allen key. (If fitting the tablet PC to the bracket, securing it with the three screws B. Using a 4mm Allen key. If fitting the DRO to the bracket, securing it with the two screws B. Using a 3/16 ” Allen key.) 3. Fit the two labelled 15-way ‘ D ’ connectors, 9-way D connector and the mains connector into the corresponding sockets at the back of the Mx200 or DRO. (No need for tablet PC.)

B

A

Figure 4

Fitting the Mx200

Projectors fitted with edge detector:

4. Fit the reference cable and screen cable connectors to the corresponding sockets at the back of the Mx200 or DRO. (If using M1 or M2, the cables already assembled inside the projector.)

3.7

Mains Connection

WARNING:

A secure earth connection must be provided. The external cable colour code is as follows:

Brown/Red

: Live

Blue

: Neutral

Green/Yellow

: Earth

The mains voltage is factory set to the correct value for the local supply; however it is recommended that the setting is checked before power is applied, as follows:

1. Refer to Section 6 - Maintenance , Figure 8 and remove the top access panel from the screen housing.

2. Identify the transformer, and check that the correct mains tapping is set.

3.

Refit the access panel.

8

1000 0193 Rev C