2.5 Safety Considerations
General Safety
NOTE: AV Series Vision Metrology Systems are designed for safety and proper ergonomics during normal use. Exercise caution when lifting, handling or moving the system to avoid personal injury and to maintain equipment calibration and measurement performance. Disconnect all power sources prior to moving or working on the equipment. Consult Starrett if you have any question regarding transporting, using or maintaining these systems. Follow all standard safety protocols for electrical and mechanical equipment in addition to all guidelines outlined in this manual. Failure to exercise proper safety practices may result in damage to the equipment, serious personal injury or death. WARNING: Follow the guidelines below to protect the equipment, to prevent voiding the warranty, and to avoid hazardous electrical conditions: Power receptacles used with this equipment must be properly grounded 3-prong polarized 120 Vac types for use in North America, or appropriate safety-rated receptacles as used outside of North America. Keep component air vents clear, clean and free from dust and debris to provide proper circulation to electrical components and to avoid overheating. Keep all liquids away from the system. Ensure that the ground is clean, dry and free from debris at all times. Do not operate the equipment in excessively humid conditions ( > 90% relative humidity). Do not operate the equipment in an explosive environment, such as around volatile or flammable solvents. Do not open the metrology cabinet or component housings, except to change light bulbs. All other components are to be serviced by factory-authorized personnel only. Do not leave covers off the machine components when operating. Disconnect power, or do not plug in the power cord, if hazardous conditions exist such as: Damaged or frayed power cord. Damaged or improperly grounded power receptacle. Equipment exposed to excessive moisture or liquid spills. Impact or damage to the equipment. Have the system inspected by authorized personnel before operating. Ongoing equipment serviced by a technician An AV (CNC) metrology stage has motorized mechanical components which move under computer control. Do not place hands or loose articles of clothing near the moving parts. Failure to observe this warning may result in personal injury and equipment damage. Familiarize yourself with operation of the system’s two E-Stop switches, as shown on page 12 of this manual. Press the closest E-Stop switch immediately if continuing motion would cause a collision or injury. Do not reapply power to the motors until the cause of the mechanical problem has been understood and removed.
Electrical Safety
Mechanical Safety
- 15 -
Made with FlippingBook - professional solution for displaying marketing and sales documents online