Portable Weld Fume Extractor
(P1200HD) CLEANING WAND
P1200HD is equipped with a cleaning wand to clean the filter
The compressed air will spin the nozzle at the end of the wand and blow
the dust from the inside of the filter
To clean the filter, attached compressed air to the end of the cleaning
wand and move the wand in and out of the filter
The recommended pressure is 90 psi
The wand only needs to be used for approximately 30-45 seconds
When cleaning the filter with the cleaning wand the filter does not need
to be removed.
After cleaning, it is recommended to clean out the dust tray within the
unit.