Clean Air Industries Portable Fume Extractor User Manual

Portable Weld Fume Extractor

(P1200HD) CLEANING WAND

P1200HD is equipped with a cleaning wand to clean the filter

The compressed air will spin the nozzle at the end of the wand and blow

the dust from the inside of the filter

To clean the filter, attached compressed air to the end of the cleaning

wand and move the wand in and out of the filter

The recommended pressure is 90 psi

The wand only needs to be used for approximately 30-45 seconds

When cleaning the filter with the cleaning wand the filter does not need

to be removed.

After cleaning, it is recommended to clean out the dust tray within the

unit.