The SeaWays GPS sensor allows heading, track, and route modes whereas the SeaWays GO compass allows heading mode. Once your Optimus EPS or Optimus 360 system is installed, adding SeaWays is simple: 1. Install the SeaWays or SeaWays GO sensor 2. Route network cable from sensor to Optimus network backbone 3. Apply sensor license provided with kit 4. SeaWays commissioning
11.4.5
SeaStation/SeaWays sensor positioning
RADIUS 36" MIN.
CLEAR VIEW OF THE SKY IN THIS REGION THIN OBJECTS LIKE FISHING RODS OR VHF ANTENNAS ARE ACCEPTABLE
10°
10°
6" MIN.
12" MIN.
METAL SURFACE OR LARGE METAL OBJECT
VHF ANTENNA BASE
FISHING ROD AND METAL HOLDER
ALUMINUM NAV. LIGHT ROD
RADAR OTHER GPS CAMERA SPOTLIGHT
CANTRAK
Figure 11-22. Sensor mounting distance from nearby VHF antennas and other equipment.
NOTICE! The sensor should be mounted as low as possible while still maintaining good sky visibility. This will reduce false movement due to the boat rocking back and forth.
The sensor is designed to withstand harsh environmental conditions.
ITEM
SPECIFICATION
Operating temperature
-30°C to +70°C (-22°F to +158°F)
Storage temperature
-40°C to +85°C (-40°F to +185°F)
Humidity
100% non-condensing
Table 11-6. Environmental conditions.
11-23
EN
Made with FlippingBook - Online Brochure Maker